Service/Maintenance
Service and adjustments performed by your Entrematic Group-authorized representative will ensure
safe and proper operation of your automatic door unit.
Remember to keep “Service Log Book” and “Site Acceptance Test and Risk Assessment” documents
available. These are used together.
The table below shows the recommended interval in months, when to replace parts during preventive
maintenance.
Abusive
Environment
Cycles/hour in operation
Part
>100<100<10
High
traffic
Medium
traffic
Low
traffic
24242424Electrical emergency unit bat-
tery
12121212Mechanical emergency unit
elastic cord
661224Floor guide shoe
Standard
Felt padded
Break-out
12122436Carriage wheel
Double
Anti-derailing
24363636Sliding track
36484848Tooth belt
60606060Drive unit damper kit
60606060Lock ramp
24364860Belt clamp
48606060Plastic protector center shaft
kit
24242424Door stop rubber kit
36363636Tension wheel assembly
60606060Detachment guard
12121212Brush/sealing