G. Compressor Assembly Will
Not Operate
1. Circuit Breaker failed or off
3. Pressure switch failed
5. Drive motor fuse blown
6. Ground power cart not plugged
in
7. Low ambient temperature
8. Low refrigerant charge
9. Motor temperature switch failed
H. No Evaporator Module Air
Flow
3. Fan speed switch failed
I. Evaporator Module Coil
Freezing
2. Expansion valve failed or
clogged
2. Remove debris or replace
3. Expansion valve setting low
3. Reset to obtain 26-30 psig
suction pressure
J Pressure Switch Cycles (High
Pressure Cutout)
1. Reclaim refrigerant as required
2. Condenser coil inlet air
extremely hot
3. Condenser inlet clogged
4. Discharge line clogged or
kinked
4. Replace or straighten line
5. Excessively high ambient
temperature
K Fault LED Light Illuminated
Inside Evaporator Motor Vent
Cap/Screen (1134200-60/-61/-63)
1. Numerous evaporator failures
can cause this indication.
1. Replace evaporator module
assembly
Table 3 Trouble Shooting List