EPSON Perfection 1240U Revision A
Assembly and Disassembly Disassembly Procedures 36
4.2.6 Carriage Motor / Timing Belt Removal
1. Release the Carriage Lock. (See Section 4.2.1.)
2. Remove the Document Cover. (See Section 4.2.2.)
3. Remove the Upper Housing. (See Section 4.2.3.)
4. Remove the Carriage Unit. (See Steps 1-8 in Section 4.2.5.)
5. Remove the six screws (gold, CBP, M3x8) and then remove the
main board cover.
6. Remove the screw (gold, CBP, M3x8) securing the CR Motor Unit.
7. Disconnect the cable for the CR Motor Unit from the connector on
the main board, and then remove the CR Motor Unit.
Figure 4-20. Shield Plate Removal
Figure 4-21. CR Motor Unit Removal
5. CBS Screw (M3x8)
5. CBS Screws (M3x8)
6. CBS Screws (M3x8)
FFC Cable
5. Main Board Cover
CR Motor Unit
7. Connector

Related product manuals