29
Chapter 2 Setup
2
DIP Switch 1 Functions
The following explains the DIP switch functions.
1 Executes the self-test once only when the power is turned on.
2 This is not available for the specifications model that has the dip switch with 8 poles.
Transfer Speed Switching
1 Default Setting
2 Settings when connecting using a serial (USB controlled)
DSW1 No. Function ON OFF Default Setting
1-1 Received Error Data Ignore Ignore "?" Display OFF
1-2 Receive Data Length 7 bit 8 bit OFF
1-3 Parity With Parity No Parity OFF
1-4 Parity Selection Even Odd OFF
1-5
Communication Speed
Switching
Refer to
" Transfer Speed Switching"
ON
1-6 OFF
1-7 ON
1-8 Execute Self-Test
*1
Yes No OFF
1-9
*2
Not used Fixed to OFF
1-10
*2
SW1-5 SW1-6 SW1-7 Transfer Speed (bps)
ON ON ON 2400
OFF ON ON 4800
ON OFF ON 9600
*1
OFF OFF ON 19200
*2
ON ON OFF 38400
OFF ON OFF 57600
ON OFF OFF 115200
OFF OFF OFF (Reserved)