EB-E01 series Disassembly and Assembly INTERNAL USE ONLY
SEIKO EPSON 160 Revision A
WRITING THE DR DATA
3. Writing the DR Data
3-1. Start up the CAT.
3-2. Select the group from SETUP / SELECT MODEL menu, by
referring to
the number; *** and xx, that can be found in a file name;
"H***_xx_yyy_zzzzz_zzzzzz_zzzzzz.bin" of supplied DR data.
3-3. Enter the 11-digit serial number of the engine noted in advance
, and run "RESTORE".
4. Image/Operation check
Restart the projector (Power OFF → Power ON) once, and confirm there
is no problem in the projected image and operation.
The DR data is not stored on a brand-new MA board, and
due to this, "$$$$$$$$" appear on the menu screen when
trying to restore the DR data, but a restore operation itself
can be completed normally.