EPSON GT-30000
3/01 EPSON GT-30000
- 3
SCSI Interface
Interface type SCSI 2 and SCSI 3
Logic level TTL-compatible
ID setting Selectable from 0 to 7
Terminator Internal terminator (enable/disable
switch selectable)
Connector select
switch W: 68-pin connector
N: 50-pin connector
Connector type Micro DB 50-pin connector
Micro DB 68-pin wide connector
Initialization
methods Hardware:
Initialized when the scanner is turned
on or the scanner receives a SCSI
Reset
signal from the SCSI interface
Software:
Initialized when the software sends
the
Esc @ (initialize the scanner
command), or the scanner receives a
SCSI Bus Device message
IEEE 1394 Scanner Interface
Interface type IEEE 1394 compatible
Data transfer
method Half-duplex Data/Strobe differential
serial
Synchronization
method Clock synchronization with DS-Link
Encoding/
decoding DS-Link
Logic level 3.3 V
Compatible
connectors IEEE 1394-1995 compatible
Power class Power class code 100
No power supply from external sources
Fitted with a repeat function with bus
power
Temperature Operating: 41 to 95 °F
(5 to 35 °C)
Standby:
−
13 to 140 °F
(−
25 to 60 °C)
Humidity
(without
condensation) Operating: 10 to 80%
Standby: 10 to 85%