EPSON Stylus Photo 750 Revision A
Disassembly and Assembly Disassembly 54
4.2.1 Housing Removal
Since this printer has no lower housing, the printer mechanism is
exposed just by removing the upper housing.
1. Open the printer cover and set the PG adjust lever on the right-hand
side to (+) position.
2. Remove 4 screws and remove the upper housing.
Figure 4-2. Housing Removal
CHECK
PO INT
Pull the front edge of the upper housing while
lifting up the upper housing to remove it.
CAUTION
Be careful not to pinch the cable with the posts of the
upper housing when reinstalling it.
Upper Housing