EPSON Stylus Photo R800 Revision A
TROUBLESHOOTING Overview 50
Table 3-7. Phenomenon-Based Paper Mismatch Error Check Points
Occurrence
Timing
Phenomenon Detail
Faulty Part/
Part Name
Check Point Remedy
At operation When print data are sent, an
error is displayed on the LED
and EPW3.
Stacker Assy. 1. Check that the Stacker Assy. setting position and paper
size set on the driver side are combined correctly.
1. Correctly combine the Stacker Assy.
setting position and paper size.
PG Release
Sensor
1. Check that the Connector cable of the PG Release Sensor
is securely connected to the PG Release Sensor and
Relay Board Connector (CN7).
1. Connect the Connector cable of the PG
Release Sensor to the PG Release
Sensor and Relay Board.
2. Check the PG Release Sensor or Connector cable for
damage.
2. Change the PG Release Sensor for a
new one.
Relay Board Connector
PG Release Sensor
Table 3-8. Phenomenon-Based Ink Low Check Points
Occurrence
Timing
Phenomenon Detail
Faulty Part/
Part Name
Check Point Remedy
At operation or
during printing
A message is displayed on
the LED and EPW3 during
printing.
Ink Cartridge 1. Look at the remaining ink indication of the EPW3 to check
the amount of the ink remaining in the Ink Cartridge.
1. Prepare a new Ink Cartridge.
Table 3-9. Phenomenon-Based Ink Out Error Check Points
Occurrence
Timing
Phenomenon Detail
Faulty Part/
Part Name
Check Point Remedy
During printing After the Carriage has
detected the HP, an error is
displayed on the LED and
EPW3.
Ink Cartridge 1. Look at the remaining ink indication of the EPW3 to check
whether the ink remains in the Ink Cartridge.
1. Change the Ink Cartridge for a new one.
Download Service Manual And Resetter Printer at http://printer1.blogspot.com