www.prolight.co.uk MaxiPar Quad User Manual
8
Operating instructions
Sound sensitivity setting:
To access sound sensitivity setting press “MENU” until the display shows SEns on the
LED display. Press the “ENTER” button and use the “UP” and “DOWN” buttons to select between
SE 1 (low) ~ SE 9 (high).
Press the “ENTER” button to conrm.
To exit out of any of the above options, press the “MENU” button.
Master dimmer setting:
To access master dimmer setting press “MENU” until the display shows dINN on the LED display.
Press the “ENTER” button and use the “UP” and “DOWN” buttons to select between
dI 1 (low brightness) ~ dI 9 (high brightness). Press the “ENTER” button to conrm.
To exit out of any of the above options, press the “MENU” button.
DMX fail setting:
To access DMX fail setting press “MENU” until the display shows FAIL on the LED display.
Press the “ENTER” button and use the “UP” and “DOWN” buttons to select between
on (when no DMX signal unit goes into last used program or sound mode) ~
off (when no DMX signal unit goes into blackout).
Press the “ENTER” button to conrm.
To exit out of any of the above options, press the “MENU” button.
Master/slave mode:
The default setting for this xture is Master. Set the master unit in one of the built-in programs, sound
modes, colour mix mode or static colour mode.
To set the slave unit, press the “MENU” button on the front of the master unit to show SLav
on the LED display. The unit is now in Slave mode.
To exit out of any of the above options, press the “MENU” button.
Please ensure that all slave units are set to the same DMX channel mode as the master unit.
IR remote setting:
To access IR remote setting press “MENU” until the display shows Infr on the LED display.
Press the “ENTER” button and use the “UP” and “DOWN” buttons to select between
on (IR receiver on) ~ off (IR receiver off).
Press the “ENTER” button to conrm.