Technical data
72/84
AFFINITY 900 ADVANCED PERFORMANCE AC PLUS
Power consumption rating with air conditioning:
Power consumption rating without air conditioning:
14800 W
Rated frequency: 50 Hz
Rated voltage: 400-415 V 3N~
or
230-240 V ~3
Rated fuses: 3 x 35 A (inactive) 3 x 50 A (inactive)
Connecting line: H05VV-F 5G 6 mm² H05VV-F 4G 10 mm²
Noise level 1m away from device: 68.9 dB(A)
Noise level inside the device: <81 dB(A)
Load on the acrylic glass panel: max. 135 kg
Weight: approx. 655 kg
AFFINITY 990 DYNAMIC PERFORMANCE AC PLUS
Power consumption rating with air conditioning:
Power consumption rating without air conditioning:
14400 W
Rated frequency: 50 Hz
Rated voltage: 400-415 V 3N~
or
230-240 V ~3
Rated fuses: 3 x 35 A (inactive) 3 x 50 A (inactive)
Connecting line: H05VV-F 5G 6 mm² H05VV-F 4G 10 mm²
Noise level 1m away from device: 68.9 dB(A)
Noise level inside the device: <81 dB(A)
Load on the acrylic glass panel: max. 135 kg
Weight: approx. 600 kg