SECTION 6 TROUBLESHOOTING
6.7 E-Stop (Emergency Stop) and Main Contactor (K1A, K1B and K1C) Circuits
Apower-upsequencetakesplacebeforetheMainContactor(K1)activates.K1isactuallythreeseparatecontactors–one
foreachprimaryinputphase.Thus,K1A,K1B,andK1CswitchphasesA,B,andCrespectivelytotheMainTransformer,T1.
Thepower-upsequencebeginswitharemoteContactorSignalactivatingK3andK33.Refertothedescriptionentitled,
Section6.6,AuxiliaryMainContactor(K3andK33)&SolidStateContactorCircuitsformoreinformation.K3andK33acti-
vatesK2closingthethreecontactsofK2.K2bypassesK1contactsprovidingprimaryinputpowertotheMainTransformer,
T1.ThiscurrentislimitedbythreeoneOhmresistors,R1,R2,andR3.Theresistorseliminatethehighsurgecurrentstypical
oftheturn-oninrushtransientsassociatedwithlargetransformers.ThehighcurrentsurgeofchargingtheBusCapacitor
BankisalsoeliminatedbyinitiallypoweringtheMainTransformerthroughK2andtheresistors.
ThedischargedBusCapacitorBankinitiallypreventstheoutputoftheMaintransformerfromreachingitsnormalvalue.
AstheBusCapacitorBankcharges,theMainTransformeroutputvoltagerisesandbecomeshighenoughforK1A,K1B,and
K1Ctoclose.OncetheK1sareclosed,thecontactsoftheStartingContactor,K2,arebypassed,andfullprimarylinepower
issuppliedtotheMainTransformerthroughthecontactsoftheK1s.
Becausethestartingsequencetakestime,itisimportantatleast300mSlapsebetweenapplyingtheContactorSignal
andapplyingloadtothepowersource.ApplyingloadtoosoonwillpreventtheK1sfromclosingandfusesF1andF2will
open.
K15,theE-Stoprelaymustbeclosedforthepower-upsequencetotakeplace.K15containsonecontactintheK2coilcircuit
andanothercontactintheK1A,K1B,&K1Ccircuits.ThereisnopowersuppliedtotheMainTransformer,T1,untilK15isacti-
vated.ForK15toactivate,S5,theE-Stopswitchonthefrontpanelmustbeclosed.Also,thePlasmaControlmustcomplete
theE-stoploopbyclosinganisolatedcontactbetweenJ1-EandJ1-F.
TheE-StopswitchisclosedwhenevertheE-Stopbutton,onthefrontpanel,ispulledout.Fortroubleshootingpurposes
only,ajumpercanbeconnectedbetweenTB8-18andTB8-19.Ifajumperisinstalled,itMUSTberemovedbeforeplacing
thepowersourcebackintoservice.Ifthejumperisnotremoved,thepowersourceE-Stopconditionwillnotfunctionwhen
theE-StopbuttonforthePlasmaControlispushed.
J4-AandJ4-BareconnectedtogetherwhenevertheE-Stopbuttononthepowersourceispulledout.Thissignalcanbe
senttothePlasmaControlsothatthecontrolsensesthestateofthepowersourceE-Stopswitch.