7 TROUBLESHOOTING
0463 341 231
- 24 -
© ESAB AB 2020
7 TROUBLESHOOTING
Try these recommended checks and inspections before sending for an authorized service
technician.
Type of fault Corrective action
No arc. Check that the main power supply
switch is turned on.
Check that the mains, welding, and
return cables are correctly connected.
Check that the correct current value is
set.
Check the electrical power supply
fuses.
The welding current is interrupted during
welding.
Check whether the overloading
protection has tripped (indicated on the
front).
Check the electrical power supply
fuses.
Check that the return cable is correctly
fastened.
The overheating protection trips frequently. Make sure that you are not exceeding
the rated data for the power source (i.e.
that the unit is not being overloaded).
Poor welding performance. Check that the welding and return
cables are correctly connected.
Check that the correct current value is
set.
Check that the correct wire or electrode
is used.
Check the electrical power supply
fuses.
Check the gas pressure in the
equipment connected to the power
source.
"Err" on display in open circuit mode Check the electrical power supply
fuses.
Check that the voltage on the voltage
selection label, on the rear of the power
source, is equal to the nominal mains
voltage.
Restart the power source with the main
switch.