Finally, press to exit Teach-in parameter edit interface.
5.2 Counting parameters
CNT 01. Current counting
Range0 — 999999
Unit
Default
CNT 02. Preset counting
Range0 — 999999
Unit
Default
Notes
1 Increasing mode: When the value of CNT01current countingincrease to the value of CNT02
preset counting,counting arrives and port exports.
2 Decreasing mode: When finishing setting parameter CNT02preset counting,the value of CNT01
current countingwill be set the same value automatically. When the value of CNT01current
countingdecrease to ‘0’, counting arrives and port exports.
3 When parameter CNT02preset countingis set as ‘0’, E10 will count and not export any output
signals.
4 If the parameter of port function for counting arrived is not set, then there will be no output.
5.3 Time relay parameters
DLY 01. T1 time setting used to set time for relay 1
Range10 — 50000
Unitms
Default1000
DLY 02. T2 time setting used to set time for relay 2
Range10 — 50000
Unitms
Default1000
DLY 03. T3 time setting used to set time for relay 3
Range10 — 50000
Unitms
Default1000
5.4 Teach in parameters
Teach-in parameters for press-braking machine
PAC 01. X-axis current position Display X-axis current position
Range0 — 999999
UnitDisplay Unit
Default 0
PAC 02. Y-axis current position Display Y-axis current position