12 www.eta.co.at
Regular maintenance Cleaning and maintenance
2.4 Regular maintenance
2.4.1 Preparation
Stop heating
Stop the heating mode of the boiler with the on / off
switch in the overview of the boiler. The boiler
emits a glowing charge and then switches to operating
mode [Switched off]. Then press the [De-ash] key
to allow the boiler to perform a final ash removal.
2.4.2 Empty the ash box
Emptying the ash box and inspecting the seals
Open the boiler door and fold the locking lever on the
boiler forward. Remove the ash box from the boiler.
Fig. 2-5: Locking lever
The openings on the ash box can be closed with
the supplied cover plate. Slide the cover plate
over the openings until it snaps into place.
Fig. 2-6: Cover plate
Fig. 2-7: Cover plate locked in place
Open the lock for the lid and empty the ash box.
Fig. 2-8: Lid
Check the ashes for pieces of embers. Never put
hot ash into the waste bin!
Check if the seal in the lid of the ash box is intact and
replace if necessary.
Fig. 2-9: Seal