EasyManua.ls Logo

eta Pellets Compact - Page 6

eta Pellets Compact
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 www.eta.co.at
Maintenance notes Cleaning and maintenance
Clean panels
If necessary, clean the panels of the boiler and the
ETAtouch screen with a moist cloth.
Under no circumstances use aggressive
solvents, chemicals or scouring agents. They can
lead to stress cracks and damage.
Wear a protective mask to avoid injuries to
the airways.
Seal the components. The sealant to use is
listed in the respective step.
Use adhesive to affix the seals, for example.
Only blow out the components with your
mouth.
Affix a seal. The required cross-section and
sealing material are given at each step.
Tighten the screws or nuts alternately and
evenly.
Do not use compressed air to clean the
components.
Do not use cleaning brushes to clean the
components.
Do not use an ash vacuum or vacuum
cleaner.
Do not lubricate the components.
No water or moisture in this area.
No leaks in the components, e.g. screw
connection or maintenance cover.

Related product manuals