Configure the Fixture 23
Set Menu
Set the Status Options
Navigate:Main Menu → Set → Status
Parameter Value Description
No DMX Mode
Close Shutter
Hold
Auto Program
Control mode when DMXis absent. The default value
is Hold.
Pan Reverse
ON
OFF
Reverse the pan movement of the fixture. The default
value is OFF.
Tilt Reverse
ON
OFF
Reverse the tilt movement of the fixture. The default
value is OFF.
Pan Degree
630
540
Change the pan rotation of the fixture from the default
setting of 540 degrees to 630 degrees.
Encoders
ON
OFF
Turn on or off the encoder feedback for pan and tilt
movement. You may want to turn off encoders when
working on a fixture so that you can move pan and tilt
without the fixture automatically moving back to
position.
Hibernation
OFF
1–99 minutes
Hibernation mode forces the LEDs and stepper motors
to power off when the fixture loses DMX control signal
for a set period of time. The default time setting is 15
minutes.
Refresh Rate
2.4 kHz
16 kHz
Set the refresh rate of the fixture. The higher 16 kHz
setting creates a beam with less "strobing" on
camera, but it is noisier than the 2.4 kHz setting.
P/T Home Mode
Standard
Tilt First
Pan First
Set the order in which pan and tilt homing is
performed.
Standard: the pan and tilt home procedures run
simultaneously.
Tilt First: the tilt home procedure runs to
completion, then the pan home procedure begins.
Pan First: the pan home procedure runs to
completion, then the tilt home procedure begins.
Dim Control
Master Base
Intensity
Independent
Base Intensity
Set the modules to which the Dimmer DMX channel is
applied.
Master Base Intensity: the Dimmer DMX channel is
applied to the Base, Flex, and Pixel modules.
Independent Base Intensity: the Dimmer DMX
channel is applied only to the Base module.