FIRST CHARGING SESSION
CHECK WHETHER THE CHARGING STATION IS WORKING
PROPERLY AND SETTING OF MAXIMAL CHARGING
CURRENT
When the charging station has either overcurrent or RCD
protection installed, check whether the protection element is in
ON position.
Connect charging station to the power supply in the electrical
cabinet. Installation feeder should be turned on.
The default value is 16 A and it can be set in range of 6 A to 32 A.
Information of the current value is obtained with short press on
the key. Number of short beeps represents information of set
maximal charging current (number of beeps x 2 A).
Settings can be accessed with key press for more than 5 s. After
that, a long beep is a notification that the settings can be
changed. Each short press on the key increments the maximal
charging current by 2 A, from minimal value of 6 A. E.g., to set
24 A, the key should be pressed 9 times.
To save the settings, press the key for more than 5 s. Long beep
is a confirmation that settings were saved, two short beeps are a
warning that settings were not saved.