6.3.2 Attempting to start
6.3.3 Removing the power pack
6.4 Use as a 12 V voltage supply
6.5 Compressor
6.5.1 Filling a tyre using the car valve (Schrader valve)
Start the motor. Do not operate the starter for longer than 6 seconds. The battery of the power pack is not designed for longer
starting attempts. Pause for at least 5 minutes between two starting attempts. If the motor does not start after a number of
attempts, abort the process and investigate the cause of the defect.
First disconnect the black (-) pole calliper, coil the cable and attach the pole calliper to the designated holder. Then disconnect
the red (+) pole calliper, coil the cable and attach the pole calliper to the designated holder. Always maintain this sequence.
Recharge the power pack.
The Power Pack can be used as a 12 V direct current source for many devices that can be operated with 12 V direct current and a
12 V motor vehicle charging cable. Plug the motor vehicle charging cable of the device you wish to operate into one of the 12 V
outlet (Position 12 in the overview). The device you wish to operate should not require a current greater than 10 A.
In order to be able to work with the compressor, rst remove the air hose from the storage compartment (Position 11 in the
overview).
Open the lock on the valve
connection
Figure 7 Figure 8 Figure 9 Figure 10
Place the valve connection on
the valve
Lock the valve connection You can now ll the tyres using
the compressor
To ll, switch the compressor on using the switch (Position 10 in the overview).
The manometer (Position 9 in the overview) is used to give a rough approximation of the air pressure. When the desired air
pressure is reached, switch the compressor o. Remove the valve connection in reverse order (Figures 10 – 7).
After lling a tyre, check the tyre pressure again using a separate air pressure tester (e.g. at a lling station, vehicle workshop).
When lling, always pay attention to the correct air pressure (consult the operating instructions of your
vehicle for information). The compressor is able to supply of pressure of up to a maximum of 18 bar. If the
pressure is too high, there is a risk of explosion and injury.
Never allow the compressor to operate for longer than 10 minutes without a pause, otherwise there is
a risk of overheating. Switch the compressor o after 10 minutes of use and allow it to cool down for at
least 10 minutes before starting it up again. Never leave the compressor to operate unattended.