During the hard blast chilling phase, the display shows the residual time of the blast chilling duration and
the
LED is on.
To modify the residual time, operate as indicated:
6.2.1 Press and release the UP or DOWN key again to modify the time value: the display will flash.
6.2.2 Do not operate for 4 s: the display will stop flashing and remain on permanently.
The successive parameters establish the following values:
- parameter r9 establishes the work set-point during the hard blast chilling phase
- parameter r14 establishes hard blast chilling phase duration.
During blast chilling, the display shows the residual time of the blast chilling duration and the
LED is
on.
The successive parameters establish the following values:
- parameter r1 establishes blast chilling duration
- parameter r7 establishes the work set-point during blast chilling.
Operate as indicated to stop the cycle:
7. Hold the START/STOP key down.
During hard blast chilling, the display shows the temperature detected by the needle probe and the
LED is on.
The successive parameters establish the following values:
- parameter r5 establishes the maximum blast chilling duration
- parameter r9 establishes the work set-point during the blast chilling hard phase
- parameter r13 establishes blast chilling hard phase end temperature.
To display the cabinet temperature, press and release the BLAST CHILLING, DEEP FREEZING or the HARD/SOFT key;
to restore the normal display, press and release the same key again or do not operate for 15 s.
When the temperature detected by the needle probe reaches the hard blast chilling phase end temperature, the device
automatically passes to blast chilling mode.
During blast chilling, the display shows the temperature detected by the needle probe and the
LED is on.
The successive parameters establish the following values:
- parameter r3 establishes the blast chilling end temperature
- parameter r5 establishes the maximum blast chilling duration
- parameter r7 establishes the work set-point during blast chilling.
To display the cabinet temperature, press and release the BLAST CHILLING key; to restore the normal display, press
and release the BLAST CHILLING key again or do not operate for 15 s.
If the temperature detected by the needle probe reaches the blast chilling end temperature within the maximum blast
chilling duration, it means that blast chilling has been completed successfully, the device will automatically pass to
storage and the buzzer will be activated for the period of time established with parameter AA.
Press and release a key to silence the buzzer.
During storage, the display shows the temperature detected by the cabinet and the
LED is on.
Parameter r10 establishes the work set-point during storage.
If the temperature detected by the needle probe does not reach the blast chilling end temperature within the
maximum blast chilling duration, blast chilling will not be completed successfully but will continue, the
LED will
flash and the buzzer will be activated.
Press and release a key to restore normal display and to silence the buzzer.
To display the cabinet temperature, press and release the BLAST CHILLING key; to restore the normal display, press
and release the BLAST CHILLING key again or do not operate for 15 s.
When the temperature detected by the needle probe reaches the blast chilling end temperature, the device
automatically passes to storage in the same way as illustrated previously.