Defrosting LED.
If it is on:
- defrosting will be in progress.
Pre-cooling LED.
If it is on:
- pre-cooling will be in progress and the cabinet temperature will have reached that established
using parameter r12.
If flashing:
- pre-cooling will be in progress and the cabinet temperature will not have reached that
established using parameter r12.
AUX
Auxiliary LED.
If it is on:
- the cabinet light will be on
- needle probe heating will be in progress
- the UV light will be on
HACCP
HACCP LED.
If it is on:
- all information regarding HACCP alarms will not have been displayed.
If flashing:
- the device will have memorised at least one new HACCP alarm.
°C
Degree Celsius LED.
If it is on:
- the temperature unit of measurement will be the degree Celsius.
°F
Degree Fahrenheit LED.
If it is on:
- the temperature unit of measurement will be the degree Fahrenheit.
min
minutes LED.
If it is on:
- the time unit of measurement will be the minute.
On/stand-by LED.
If it is on:
- the device will be in the “stand-by” status.