14 TECHNICAL DATA
14.1 Technical data
Purpose of the device: blast chiller controller.
user interface control module
Execution:
board without cover behind a
Plexiglas sheet.
board without cover.
user interface control module
Dimensions:
290.0 x 50.5 x 38.0 mm
(11.417 x 1.988 x 1.496 in;
L x H x P).
99.0 x 108.0 x 24.0 mm (3.897
x 4.251 x 23.978 mm; L x H x
D).
user interface control module
Installation:
rear of panel, with biadhesive
tape.
on flat surface, with spacers.
user interface control module
Protection rating:
IP65. IP00.
user interface control module
fixed screw terminal boards
(control module).
fixed screw terminal board
(user interface and inputs), 6.3
m faston (0.248 in, power
supply and outputs), 6 pole
connector (serial port).
Connections:
The maximum length of the user interface
-control module connection is 20 m (65.614 ft).
Temperature of use: from 0 to 55 °C (from 32 to 131 °F).
Storage temperature: from -25 to 60 °C (from -13 to 140 F).
Humidity for use: from 10% to 90% relative humidity without condensate.
Pollution situation: 2.
Power supply:
user interface control module