RampMaster II Display Conditions
Display Alternating Between IdLE (Idle) and Temperature
Program is not running: kiln chamber temperature is displayed.
Display Reading Temperature
Program is running and is ramping to temperature: kiln chamber temperature is displayed.
Display Alternating Between Time Value and Temperature
Program is running and is holding at temperature: kiln chamber temperature is displayed along with the time value counting down remaining
hold time.
Display Reading a Decreasing Time Value
Program is running with a delay start: the time value counting down is the remaining delay start time.
Dot Displayed Between the 10’s and 100’s Digits
Indicates the value being displayed is a time value.
Dot Displayed to the Right of the 1’s Digit
Indicates that a Celsius temperature is being displayed. If no dot is displayed the RampMaster II is displaying in Fahrenheit.
Display Alternating Between Any Value and ERRP
Indicates a brief power failure has occurred. In this condition the RampMaster II continues to run the program.
Display Reading PF
Indicates an extended power failure has occurred. In this condition the RampMaster II stops running the program.

Other manuals for Evenheat RampMaster II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Evenheat RampMaster II and is the answer not in the manual?

Evenheat RampMaster II Specifications

General IconGeneral
BrandEvenheat
ModelRampMaster II
CategoryController
LanguageEnglish

Related product manuals