THANK YOU
We appreciate the trust and confidence you have placed in Everbilt through the purchase of this non-submersible sump pump. We strive to
continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home
improvement needs. Thank you for choosing Everbilt!
SKU# 1000026686 1000026682
1000026675 1000026662
Model# SP03302VD SP05002VD
PSSP07501VD PSSP10001VD
USE AND CARE GUIDE
SUBMERSIBLE SUMP PUMP
Questions, problems, missing parts? Before returning to the store call
Everbilt Customer Service
8 a.m. - 6 p.m., EST, Monday-Friday
1-844-241-5521
HOMEDEPOT.COM
Rev. 05/20/17
SKU # 1000026675 SKU #1000026662
SKU # 1000026686 SKU # 1000026682

Questions and Answers

  • E
    Erik JonesJul 25, 2025
    How to fix an Everbilt Water Pump that pumps little or no water?
    • D
      Diana GutierrezJul 25, 2025
      If your Everbilt Water Pump is running but not pumping much water, check for a blocked screen (clean the screen). Also, look for debris caught in the impeller or discharge (remove the debris). Finally, inspect the impeller to see if it is loose on the shaft or broken (reassemble or replace the impeller).
  • M
    Matthew RoweJul 29, 2025
    Why does my Everbilt PSSP10001VD not start?
    • M
      Mr. James WrightJul 29, 2025
      There are several reasons why your Everbilt Water Pump might not be starting. It could be due to a blown fuse (replace the fuse), a tripped breaker (reset the breaker), or a disconnected plug (secure the plug). A corroded plug (clean the plug prongs), thermal overload (unplug for 30 minutes and then plug in again), a failed switch (replace the switch), or a failed motor (replace the pump) could also be the cause.
  • M
    Maria RoweAug 3, 2025
    What to do if my Everbilt Water Pump starts and stops too often?
    • B
      barajascarlosAug 3, 2025
      If your Everbilt Water Pump is starting and stopping too often, it could be due to a backflow of water from the piping or a leaking check valve (install or replace the check valve). Another possibility is that the float switch is stuck (clean the float switch rod to ensure free movement).
  • C
    Carly LewisAug 7, 2025
    What to do if Everbilt PSSP10001VD Water Pump will not shut off?
    • J
      Jeffrey HolmesAug 7, 2025
      If your Everbilt Water Pump won't shut off, it might be because the switch is tangled (reposition the pump and ensure the switch moves freely), the float switch is faulty (replace the switch), or the float is obstructed (remove the obstruction).
  • M
    Mrs. Laura MartinAug 11, 2025
    Why my Everbilt PSSP10001VD Water Pump won't start?
    • C
      Chelsea EllisAug 12, 2025
      If your Everbilt Water Pump isn't starting, there could be several reasons: * No power: Try resetting the GFCI switch or breaker, ensure the plug is secure, and clean the plug prongs. * Blocked impeller: Remove any debris around the impeller. * Faulty float switch: Replace the float switch. * Motor failure: It may be necessary to replace the entire pump.
  • J
    jessicawilliamsAug 16, 2025
    How to fix Everbilt PSSP10001VD Water Pump that pumps little water?
    • D
      Desiree JohnsonAug 16, 2025
      If your Everbilt Water Pump is running but not pumping much water, check for these issues: * Blocked screen: Clean the screen. * Debris in impeller or discharge: Remove any obstructions. * Broken impeller: Replace the impeller.
  • R
    rodriguezbrandonAug 20, 2025
    What to do if my Everbilt PSSP10001VD will not shut off?
    • K
      Kelli RobinsonAug 20, 2025
      If your Everbilt Water Pump won't shut off, it might be due to: * Tangled float switch: Reposition the pump to allow the switch to move freely. * Failed float switch: Replace the float switch.

Summary

Safety Information

Handling and Operation Hazards

Warnings about pumping flammable liquids, touching hot motor housing, and handling pump with wet hands.

Electrical Safety Requirements

Guidelines on using 115V, 3-prong plugs, protecting electrical cords, and ensuring proper grounding.

Extension Cord Usage Precautions

Advisory on potential hazards and insufficient voltage delivery from extension cords.

Personal Protective Equipment

Recommendation to wear safety goggles at all times when working with pumps.

Safety Information (continued)

Operational Precautions

Cautions regarding pump applications, securing to a base, periodic inspection, and following codes.

Power Source and Material Integrity

Important notes on adequate power source and pump material durability, including thermal protection.

Warranty

Product Warranty Coverage

Details the 5-year and 3-year warranty periods for materials and workmanship from date of purchase.

Warranty Limitations and Exclusions

Outlines what is not covered, including misuse, accident, and exclusions for consequential damages.

Pre-Installation

Application Guidelines

Specifies the pump is for home sump applications only and not for salt water or pools.

Tools and Materials Required

Lists necessary tools and materials (not included) for installation, such as PVC primer and cement.

Pre-Installation (continued)

Package Contents

Identifies the components included in the package, noting the adapter may not be shown to scale.

Pump Specifications

Details power supply, temperature range, discharge size, sump basin requirements, and switch settings.

Installation

Sump Pit and Pump Placement

Instructions for installing the pump in a sump pit, ensuring clearance for the switch mechanism.

Discharge Plumbing and Check Valve

Steps for installing discharge pipes, PTFE tape, and check valves, including air bleed hole drilling.

Power Supply Connection

Requirement for a 115V, 60 Hz, 15 amp circuit and a GFCI power outlet for safe operation.

Installation (continued)

Discharge Line Freeze Protection

Guidance on installing exposed discharge lines to prevent water freezing and pump damage.

Operational Check Procedure

Steps to check pump operation by filling the sump with water and observing a full cycle.

Operation

Lubrication and Dry Run Prevention

Emphasizes the need for water lubrication for the shaft seal and avoiding dry running.

Thermal Protector Function

Explains the automatic reset thermal protector and causes for repeated tripping.

Manual Operation and Prime Loss

Advice on shutting off the unit if no water comes out, indicating low water level or broken prime.

Care and Cleaning

Safe Handling and Cooling

Caution to use the handle, not the power cord, and allow the pump to cool before touching.

Cleaning a Clogged Pump

Step-by-step guide to unplug, disassemble, clean debris from the impeller, and reassemble.

Prohibited Disassembly

Warning against disassembling the motor housing due to repairability and electrical risks.

Troubleshooting

Pump Does Not Start or Run

Identifies possible causes like no power, blocked impeller, or float switch failure, with corrective actions.

Low Water Output Issues

Addresses causes like blocked screens or debris in impeller, and provides cleaning or replacement steps.

Intermittent Starting and Stopping

Explains causes such as backflow or float switch issues and suggests installing check valves or cleaning switches.

Pump Fails to Shut Off

Covers reasons like tangled or failed float switches, recommending repositioning or replacement.

Everbilt PSSP10001VD Specifications

General IconGeneral
Model NumberPSSP10001VD
CategoryWater Pump
TypeSubmersible
Voltage120V
Maximum Head25 ft
Discharge Diameter1-1/4 in
Power Cord Length10 ft
Maximum pumping height25 ft
Outlet size1-1/4 in
MaterialThermoplastic
Horsepower1 HP