THANK YOU
We appreciate the trust and confidence you have placed in Everbilt through the purchase of this 1/4 HP submersible pool
cover pump. We strive to continually create quality products designed to enhance your home. Visit us online to see our full
line of products available for your home improvement needs. Thank you for choosing Everbilt!
Item # 1004181632
Model # EBAU25-PCP
USE AND CARE GUIDE
1/4 HP SUBMERSIBLE POOL COVER PUMP
Questions, problems, missing parts? Before returning to the store,
call Everbilt Customer Service
8 a.m. - 5 p.m., EST, Monday-Friday
1-844-251-7446
HOMEDEPOT.COM

Questions and Answers

Summary

Performance

Safety Information

DANGER: Do not pump flammable or explosive liquids

Warnings against pumping flammable liquids like gasoline, oil, and kerosene.

DANGER: RISK OF ELECTRICAL SHOCK

Ensuring the pump is connected to a properly grounded receptacle.

DANGER: Do not handle the pump with wet hands

Precautions for handling the pump when wet or standing in water.

DANGER: Never touch any electrical device

Safety advice when working with electrical devices in moist environments.

DANGER: Never use this pump in or around a swimming pool

Prohibition of using the pump in swimming pools with people present.

WARNING: GFCI plug connection advice

Advice on connecting GFCI plugs to avoid nuisance tripping.

WARNING: Freezing temperature precautions

Warning about leaving the pump outside during freezing temperatures.

WARNING: Consequences of non-compliance

Consequences of non-compliance and using damaged pumps.

WARNING: Do not disassemble the motor housing

Prohibition of motor housing disassembly due to safety risks.

WARNING: Unit electrical requirements

Electrical specifications and grounding requirements for the pump.

WARNING: Handling the pump

Instructions on how to carry the pump using the handle.

WARNING: Secure the discharge line

Securing the discharge line to prevent whipping and injury.

WARNING: Release pressure before servicing

Procedure for draining water before servicing any component.

WARNING: Wear safety goggles

Recommendation to wear safety goggles during operation.

WARNING: Direct outlet connection

Advice on using extension cords and direct connection to outlets.

WARNING: Protect the electrical cord

Protecting the power cord from sharp objects, heat, oil, and chemicals.

WARNING: Electrical circuit protection

Ensuring the electrical circuit is protected by a 15-amp fuse/breaker.

WARNING: Pump orientation

Guidance on keeping the pump straight and intake clear.

CAUTION: Periodic inspection

Regular inspection of the pump and system components.

CAUTION: Know pump limitations

Understanding the pump's applications, limitations, and hazards.

CAUTION: Follow safety codes

Adherence to electrical and safety codes like NEC and OSHA.

IMPORTANT: Adequate power supply

Ensuring the electrical power source is adequate for pump requirements.

IMPORTANT: Thermal protector

Information on the automatic thermal protector and its overuse.

IMPORTANT: Material properties

Details on pump materials and factors causing failure.

IMPORTANT: Sewage;septic system restriction

Restrictions on using the pump in sewage or septic systems.

IMPORTANT: Sump pump restriction

Restrictions on using the pump as a permanent sump pump.

Warranty

Pre-installation

Application

Details the intended uses and applications for the submersible pool cover pump.

Tools Required

Lists the necessary tools for the installation process.

SPECIFICATIONS

Installation

Attaching the pool cover base to the pump

Step-by-step instructions for attaching the pool cover base to the pump.

Connecting the adapter

Instructions for connecting the garden hose adapter to the pump discharge.

Connecting the discharge hose

Steps for connecting a 3/4 in. garden hose to the pump adapter.

Placing the pump on the pool cover

Guidance on positioning the pump on the pool cover for proper operation.

Operation

Operating the pump

Detailed steps for operating the pump, including GFCI checks and float switch function.

Care and Cleaning

Recommended actions for cleaning

Steps to inspect, clean debris from the pump, and reassemble.

Actions to avoid during maintenance

Prohibitions on disassembling the motor housing or lifting by the power cord.

Troubleshooting

Low flow or no discharge issues

Diagnosing and fixing problems like blocked intake, airlocks, or kinked hoses.

Pump not running or humming

Troubleshooting issues related to the pump not starting or humming.

Pump overheating issues

Addressing problems where the pump has overheated due to thermal overload.

Liquid temperature issues

Troubleshooting based on liquid temperature being too low or too high.

Motor failure diagnosis

Identifying and addressing situations where the motor has failed.

Summary

Performance

Safety Information

DANGER: Do not pump flammable or explosive liquids

Warnings against pumping flammable liquids like gasoline, oil, and kerosene.

DANGER: RISK OF ELECTRICAL SHOCK

Ensuring the pump is connected to a properly grounded receptacle.

DANGER: Do not handle the pump with wet hands

Precautions for handling the pump when wet or standing in water.

DANGER: Never touch any electrical device

Safety advice when working with electrical devices in moist environments.

DANGER: Never use this pump in or around a swimming pool

Prohibition of using the pump in swimming pools with people present.

WARNING: GFCI plug connection advice

Advice on connecting GFCI plugs to avoid nuisance tripping.

WARNING: Freezing temperature precautions

Warning about leaving the pump outside during freezing temperatures.

WARNING: Consequences of non-compliance

Consequences of non-compliance and using damaged pumps.

WARNING: Do not disassemble the motor housing

Prohibition of motor housing disassembly due to safety risks.

WARNING: Unit electrical requirements

Electrical specifications and grounding requirements for the pump.

WARNING: Handling the pump

Instructions on how to carry the pump using the handle.

WARNING: Secure the discharge line

Securing the discharge line to prevent whipping and injury.

WARNING: Release pressure before servicing

Procedure for draining water before servicing any component.

WARNING: Wear safety goggles

Recommendation to wear safety goggles during operation.

WARNING: Direct outlet connection

Advice on using extension cords and direct connection to outlets.

WARNING: Protect the electrical cord

Protecting the power cord from sharp objects, heat, oil, and chemicals.

WARNING: Electrical circuit protection

Ensuring the electrical circuit is protected by a 15-amp fuse/breaker.

WARNING: Pump orientation

Guidance on keeping the pump straight and intake clear.

CAUTION: Periodic inspection

Regular inspection of the pump and system components.

CAUTION: Know pump limitations

Understanding the pump's applications, limitations, and hazards.

CAUTION: Follow safety codes

Adherence to electrical and safety codes like NEC and OSHA.

IMPORTANT: Adequate power supply

Ensuring the electrical power source is adequate for pump requirements.

IMPORTANT: Thermal protector

Information on the automatic thermal protector and its overuse.

IMPORTANT: Material properties

Details on pump materials and factors causing failure.

IMPORTANT: Sewage;septic system restriction

Restrictions on using the pump in sewage or septic systems.

IMPORTANT: Sump pump restriction

Restrictions on using the pump as a permanent sump pump.

Warranty

Pre-installation

Application

Details the intended uses and applications for the submersible pool cover pump.

Tools Required

Lists the necessary tools for the installation process.

SPECIFICATIONS

Installation

Attaching the pool cover base to the pump

Step-by-step instructions for attaching the pool cover base to the pump.

Connecting the adapter

Instructions for connecting the garden hose adapter to the pump discharge.

Connecting the discharge hose

Steps for connecting a 3/4 in. garden hose to the pump adapter.

Placing the pump on the pool cover

Guidance on positioning the pump on the pool cover for proper operation.

Operation

Operating the pump

Detailed steps for operating the pump, including GFCI checks and float switch function.

Care and Cleaning

Recommended actions for cleaning

Steps to inspect, clean debris from the pump, and reassemble.

Actions to avoid during maintenance

Prohibitions on disassembling the motor housing or lifting by the power cord.

Troubleshooting

Low flow or no discharge issues

Diagnosing and fixing problems like blocked intake, airlocks, or kinked hoses.

Pump not running or humming

Troubleshooting issues related to the pump not starting or humming.

Pump overheating issues

Addressing problems where the pump has overheated due to thermal overload.

Liquid temperature issues

Troubleshooting based on liquid temperature being too low or too high.

Motor failure diagnosis

Identifying and addressing situations where the motor has failed.

Overview

The Everbilt 1/4 HP Submersible Pool Cover Pump (Item # 1004181632, Model # EBAU25-PCP) is a utility pump designed primarily for removing water from swimming pool covers. Its automatic operation allows it to be left plugged in without constant monitoring, as it will shut off once the water has been removed. While ideal for pool covers, it can also be used for general water removal applications in flooded areas, window wells, low spots in yards, clogged sinks, water basins, boats, and stock tanks.

Important Technical Specifications:

  • Power Supply: 115V, 60 Hz
  • Liquid Temperature Range: 32°F to 95°F (0°-35°C)
  • Individual Branch Circuit Required: 15 Amp Minimum
  • Discharge Connection: 1-1/4 in. Male NPT or 3/4 in. garden hose connection
  • Discharge Hose Needed: 1-1/4 in. Flexible Discharge Hose or 3/4 in. garden hose
  • Power Cord: SJTW, 18AWG/3C, 25 ft.
  • Performance (at 1-1/4 in. discharge):
    • 0 ft. of lift: 24 GPM
    • 5 ft. of lift: 22 GPM
    • 10 ft. of lift: 19 GPM
    • 15 ft. of lift: 14 GPM
    • 20 ft. of lift: 4 GPM
  • Max Lift: 21.5 ft.

Usage Features:

  • Automatic Operation: The pump features a float switch that activates when water reaches at least 2-1/4 inches around the pump and shuts off when water is pumped down to approximately 11/16 inches, running for an additional 30-60 seconds before stopping. This allows for hands-free operation.
  • Ground Fault Circuit Interrupter (GFCI) Plug: The pump is equipped with a GFCI plug for electrical safety. Users should check the GFCI if the pump is not running and reset it if tripped. It's recommended to connect the pump directly to a grounded outlet.
  • Versatile Discharge Options: The pump can connect to either a 1-1/4 inch flexible discharge hose for maximum flow rate or a standard 3/4 inch garden hose. For optimal performance, hose lengths should be kept as short as possible (50 ft. or less for garden hoses) to prevent flow restriction.
  • Pool Cover Base: The pump includes a pool cover base that helps stabilize it on the cover and allows for efficient water intake. This base can be removed for general water removal applications.
  • Thermal Protector: The motor has an automatic resetting thermal protector that turns the pump off if it becomes too hot. Overuse of this feature can damage the pump and void the warranty.
  • Corrosion-Resistant Materials: Constructed from high-strength, corrosion-resistant materials, the pump is designed for durability and long-term service.

Important Usage Warnings and Limitations:

  • Flammable Liquids: Never pump flammable or explosive liquids (e.g., gasoline, oil, kerosene, ethanol) or use in the presence of flammable vapors, as this can cause explosion or fire.
  • Electrical Safety: Always disconnect the pump from its power source before servicing. Do not handle the pump with wet hands or when standing on a wet or damp surface or in water while it is plugged in. Never touch any electrical device in water.
  • Grounding: The pump is supplied with a grounding conductor and a 3-prong grounding-type attachment plug. Do not remove the ground pin. Connect only to a properly grounded receptacle.
  • Extension Cords: If an extension cord is necessary, use a shorter, heavier gauge cord (16-gauge or thicker for a 25 ft. cord) to ensure sufficient voltage. Prevent the extension cord ends from getting wet. The GFCI plug will not protect against shock hazards from the extension cord itself.
  • Freezing Temperatures: Do not leave the pump plugged in and outside when freezing temperatures are expected, as this can damage the pump.
  • Damaged Pump: Do not attempt to use a damaged pump, as it can result in property damage, serious personal injury, and/or death.
  • Motor Housing: Do not disassemble the motor housing, as it contains no repairable internal parts, and disassembly will void the warranty and may cause dangerous electrical wiring issues.
  • Discharge Hose: Secure the discharge line before starting the pump to prevent it from whipping and causing injury or property damage. Do not suspend the pump by the discharge hose or power cord.
  • Pump Placement: Place the pump as straight as possible on the pool cover to ensure the float switch operates properly. Avoid coiling or kinking the hose.
  • Water Type: This pump is designed to pump rainwater from pool covers, not chlorinated pool water. It has not been tested or approved for use in swimming pools or salt-water marine areas.
  • Continuous Operation: Not engineered for continuous operation as a "fountain" or "waterfall" pump, or in any other water re-circulation process.
  • Sump Pump Replacement: Not intended to be used as a permanent sump pump.

Maintenance Features:

  • Debris Removal: Periodically inspect the pool cover base and pump intake screen (bottom of pump) and remove any debris. A clear path for water is crucial for optimal performance.
  • Cleaning Clogged Pump:
    1. Unplug the pump from electrical power.
    2. Remove the screws and pool cover base from the pump.
    3. Remove the screws and screen from the bottom of the pump.
    4. Remove the screws, volute, and seal gasket from the pump.
    5. Clean debris from the impeller and pool cover base.
    6. Reassemble the components.
  • Float Switch Maintenance: If debris prevents the float switch from operating, remove any debris from the float switch cage on the side of the pump. The bottom portion of this cage can be removed for further cleaning.
  • General Inspection: Periodically inspect the pump and system components to ensure the pump intake is free of mud, sand, and debris. Disconnect from power supply before inspecting.
  • Cord Protection: Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord and do not use damaged or worn cords.

For questions, problems, missing parts, or replacement parts, contact Everbilt Customer Service at 1-844-251-7446, Monday-Friday, 8 a.m. - 5 p.m. EST, or visit HOMEDEPOT.COM.

Everbilt EBAU25-PCP Specifications

General IconGeneral
BrandEverbilt
ModelEBAU25-PCP
CategoryWater Pump
LanguageEnglish

Related product manuals