EVO EXPANDED SYSTEM
Connect the rst Optical Output of the EVO 16 to the Optical Input of
the rst EVO SP8 and the second optical Output of the EVO 16 to the
rst Optical input of the second EVO SP8. This will require two TOSlink
cables.
Connect the Optical Inputs of the EVO 16 to the Optical Outputs of
the EVO SP8’s, in the same manner, using a further two TOSlink cables.
Connect a BNC T-Bar connector to the Word Clock Input of the rst
SP8.
Connect a BNC word clock cable from the Word Clock Output of the
EVO 16 into one side of the T-Connector.
Connect a second word clock cable from the other side of the
T-Connector into the Word Clock Input of the second EVO SP8.
On both SP8s use the Setup Menu to set the clock source to ‘Word
Clock’. On the rst SP8, set the Word Clock Termination to ‘O. On
the second SP8, set the Word Clock Termination to ‘On. Also set the
Sample Rate to ‘Auto’ on both units
On the EVO 16, ensure that its clock source is set to ‘Internal’ and the
Optical format is set to ‘ADAT’ in the EVO Software Mixer Applications