EVO EXPANDED SYSTEM
Connect the rst Optical Output of the host interface to the Optical
Input of the rst EVO SP8 and the second Optical Output of the host
interface to the rst Optical Input of the second EVO SP8. This will use
2 TOSlink cables.
Connect the Optical Inputs of the host interface to the Optical Outputs
of the EVO SP8s, in the same manner, using a further 2 TOSlink cables.
Connect a BNC T-Bar connector to the Word Clock Input of the rst
SP8, the part with the rotating barrel should lock onto the SP8.
Connect a BNC word clock cable from the Word Clock Output of the
host interface into one side of the T-Connector.
Connect a second word clock cable from the other side of the
T-Connector into the Word Clock Input of the second EVO SP8.
On the host interface, ensure that its clock source is set to ‘Internal’.
On both SP8s use the Setup Menu to set the clock source to ‘Word
Clock’. On the rst SP8, set the Word Clock Termination to ‘O. On
the second SP8, set the Word Clock Termination to ‘On. Also set the
Sample Rate to ‘Auto’ on both units.
1.
2.
3.
4.
5.
6.
7.