040112XX
EXCELL PRECISION CO., LTD
ZSME400000005
68
BCD Parallel Output Interface (OP 02)
Item
Function
Setting value
Default
Parameter
Description
bCd- 01
Data type
0
As display
0
1
Gross
2
Net
bCd- 02
Transmit mode
0
Transmit continuous
0
1
Auto transmit
2
Manual transmit
bCd- 03
Output Logic
0
Positive logic action
0
1
Negative logic action
bCd- 04
Data ready
Signal logic
0
Positive logic action
0
1
Negative logic action
bCd- 05
OL output code
0
FFFFFF
0
1
999999
bCd- 06
Data code
0
BCD Code
0
1
Hex. Code
Analogue Current/Voltage Output Interface (Op - 03)
Item
Function
Setting value
Default
Parameter
Description
AnL- 01
Data type
0
As display
0
1
Gross
2
Net
AnL- 02
Signal output
0
Current output
0
1
Voltage output
AnL- 03
Weight in Lo
000000 ~ 999999
When the weight reaches the value of
that in AnL-03(the Max. weight is the
max setting value (refer to CSP-04 ),
the current / voltage(refer to AnL-02)
output is changed to that configured in
AnL-04
0
AnL- 04
Current / Voltage
in Lo
4.0 mA ~ 20.0 mA
or
0.0 V ~ 10.0 V
4.0
AnL- 05
Weight in Hi
000000 ~ 999999
When the weight reaches the value of
that in AnL-05(the Max. weight is the
max setting value (refer to CSP-04 ),
the current / voltage(refer to AnL-02)
output is changed to that configured in
AnL-06
30000
AnL- 06
Current / Voltage
in Hi
4.0 mA ~ 20.0 mA
or
0.0 V ~ 10.0 V
20.0