EasyManuals Logo

Excell 150S User Manual

Excell 150S
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #72 background imageLoading...
Page #72 background image
040112XX
EXCELL PRECISION CO., LTD
ZSME400000005
71
Item
Function
Setting value
Default
Parameter
Description
SQ- 10
Discharge start delay
time
0.0 ~ 25.5
(sec)
Delay time before Discharge signal is ON
0.0
SQ- 11
Discharge stop delay
time
0.0 ~ 25.5
(sec)
Delay time before Discharge signal is OFF
0.0
SQ- 12
Discharge time
0.0 ~ 25.5
(sec)
Won’t activate internal discharge control
function, if set to 0
0
Discharge input signal
Weight reach zero band
SQ- 10
Discharge output signal
SQ- 11
SQ- 13
Restart delay time
0.0 ~ 25.5
(sec)
Delay time before Restart signal is ON
1.0
SQ- 14
Batching counts
0 ~ 255
(times)
Number of batch runs
0 one batch only
0
SQ- 15
Set the zero band in to
final weighing value
0
No setting
0
1
Setting
SQ- 16
Hi, OK, Lo
0
Comparison anytime
0
1
To compare at batch finish
2
To compare at external input signal
3
To compare at batching finish and external
input signal
4
Comparison auto
SQ- 17
Auto totalise weight /
counts
0
Disabled
0
1
Enabled
SQ- 18
The parameter
source in weight
comparison
0
Key in directly from front keypad
0
1
Input directly from rear interface
SQ- 19
Weight comparison
delay time
0.0 ~ 25.5
(sec)
Comparison delay time for Hi, OK, Lo
0.5
SQ- 20
TARE auto.
0
Press keypad TARE to TARE
0
1
TARE auto
SQ- 21
Discharge auto
0
Input from external input or keypad
0
1
Discharge auto + manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Excell 150S and is the answer not in the manual?

Excell 150S Specifications

General IconGeneral
BrandExcell
Model150S
CategoryController
LanguageEnglish

Related product manuals