Watt Hour (Active Power Hour): WH
Range
Resolution
Accuracy
0.000 to 9.999 KWH
0.001 KWH
± (2%+0.008 KWH)
10.00 to 99.99 KWH
0.01 KWH
± (2%+0.08 KWH)
100.0 to 999.9 KWH
0.1 KWH
± (2%+0.8 KWH)
1.000 to 9.999 MWH
0.001 MWH
± (2%+0.008 MWH)
VA Hour (Apparent Power Hour): SH
Range
Resolution
Accuracy
0.000 to 9.999 KVAH
0.001 KVAH
± (2%+0.008 KVAH)
10.00 to 99.99 KVAH
0.01 KVAH
± (2%+0.08 KVAH)
100.0 to 999.9 KVAH
0.1 KVAH
± (2%+0.8 KVAH)
1.000 to 9.999 MVAH
0.001 MVAH
± (2%+0.008 MVAH)
VAR Hour (Reactive Power Hour): QH
Range
Resolution
Accuracy
0.000 to 9.999 KVARH
0.001 KVARH
± (2%+0.008 KVARH)
10.00 to 99.99 KVARH
0.01 KVARH
± (2%+0.08 KVARH)
100.0 to 999.9 KVARH
0.1 KVARH
± (2%+0.8 KVARH)
1.000 to 9.999 MVARH
0.001 MVARH
± (2%+0.008 MVARH)