EasyManuals Logo

Extech Instruments CO240 User Manual

Extech Instruments CO240
8 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
8 CO240-en-US_v1.9 10/22
Two-year Warranty
Teledyne FLIR warrants this Extech brand instrument to be free of defects in parts and
workmanship for two years from date of shipment (a six-month limited warranty applies to sensors
and cables). To view the full warranty text please visit:
http://www.extech.com/support/warranties.
Calibration and Repair Services
Teledyne FLIR offers calibration and repair services for the Extech brand products we sell. We
offer NIST traceable calibration for most of our products. Contact us for information on calibration
and repair availability, refer to the contact information below. Annual calibrations should be
performed to verify meter performance and accuracy. Product specifications are subject to change
without notice. Please visit our website for the most up-to-date product information:
www.extech.com.
Contact Customer Support
Customer Support Telephone List: https://support.flir.com/contact
Calibration, Repair, and Returns: repair@extech.com
Technical Support: https://support.flir.com
Copyright © 2022 Teledyne FLIR Commercial Systems, Inc.
All rights reserved including the right of reproduction in whole or in part in any form
www.extech.com
This document does not contain any export-controlled information

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extech Instruments CO240 and is the answer not in the manual?

Extech Instruments CO240 Specifications

Display and Measurement IconDisplay and Measurement
displayDual multifunction LCD
CO2 measure range0 to 9, 999 ppm
CO2 accuracy± (75 ppm + 5% of reading) 0 to 2, 000 ppm
Operating Environment IconOperating Environment
operating temperature0 to 50°C (32 to 122°F); 0.1° resolution
operating relative humidity0 to 95% RH (avoid condensation)
relative humidity accuracy± 5% of rdg at 25°C (77°F) otherwise ±7% RH
Temperature Ranges IconTemperature Ranges
dew point temperature range‐72.9 to 47°C (‐99.22 to 118°F); 0.1° resolution
wet bulb temperature range‐11 to 48.2°C (12.2 to 118.8°F); 0.1° resolution
temperature accuracy± 1°C (1.8 °F)
Storage Conditions IconStorage Conditions
storage temperature‐20 to 50°C (‐4 to 122°F)
storage humidity0 to 95% RH (avoid condensation)
dimensions211 x 60 x 40 mm (8.3 x 2.4 x 1.6")
Power and Weight IconPower and Weight
powerAAA batteries x 6 pcs or AC adaptor
weight181.4 g (6.4 oz.)