Replacing the Fuses
1. Open the battery/fuse door by loosening the two screws on the battery/fuse door using a Phillips head
screwdriver.
2. Remove the old fuse from its holder by gently pulling it out.
3. To access the 20A fuse, remove the third screw under the tilt stand, remove the back cover and gently lift the
printed circuit boards.
4. Install the new fuse into the holder.
5. Always use a fuse of the proper size and value (0.5A/250V fast blow for the 400mA range 20A/250V fast blow for
the 20A range.
6. Put the battery/fuse door back in place. Insert the screws and tighten securely.