Datalogging
Types of Data Recording
Manual Datalogging: Manually log up to 99 readings onto an SD card via push-button press.
Automatic Datalogging: Automatically log data onto an SD memory card where the number of
data points is virtually limited only by the card size. Readings are logged at a rate specified by
the user.
SD Card Information
Insert an SD card (from 1G size up to 16G) into the SD card slot at the bottom of the meter. The
card must be inserted with the front of the card (label side) facing toward the rear of the meter.
If the SD card is being used for the first time it is recommended that the card be formatted and
the logger’s clock set to allow for accurate date/time stamping during datalogging sessions.
Refer to the Setup Mode section for SD card formatting and time/date setting instructions.
European and USA numerical formats differ. The data on the SD card can be formatted for
either format. The meter defaults to USA mode where a decimal point is used to separate units
from tenths, i.e. 20.00. The European format uses a comma, i.e. 20,00. To change this setting,
refer to the Setup Mode section.
Manual Datalogging
In the manual mode the user presses the LOG button to manually log a reading onto the SD card.
1. Set the sampling rate to ‘0’ seconds as described in the Setup Mode section.
2. Press and hold the LOG button for at least 1.5 seconds and the DATALOGGER icon will appear
on the LCD; the lower portion of the display will show p-n (n = memory position number 1-99).
Note that if PSI is set as the unit of measure it appears as P51 (where a ‘5’ is used as an ‘S’) in
the same area of the LCD where memory locations are shown. This can be disorienting at first.
3. Momentarily press the LOG button to store a reading. The DATALOGGER icon will flash each
time a data point is stored.
4. Use the and buttons to select one of the 99 data memory positions in which to record.
5. To exit the manual datalogging mode, press and hold the LOG button for at least 1.5 seconds.
The DATALOGGER icon will switch off.
www.burntec.com
Question and Answer IconNeed help?

Do you have a question about the Extech Instruments SDL800 and is the answer not in the manual?

Extech Instruments SDL800 Specifications

General IconGeneral
BrandExtech Instruments
ModelSDL800
CategoryMeasuring Instruments
LanguageEnglish

Summary

Introduction

Safety

International Safety Symbols

Symbol indicating the user must refer to the manual for further information.

Meter Description

Getting Started

Power ON-OFF

Instructions for powering the meter on and off, and battery/adapter usage.

Display Backlight

How to turn the display backlight on or off using the backlight button.

Vibration Sensor

Connecting the vibration pickup to the meter and handling for magnetic surfaces.

Units of Measure

How to change the measurement units displayed on the LCD.

Function Selection

MAX HOLD Reset

Procedure to clear the max Hold reading using the up and down buttons.

Data Hold

Freezing a displayed reading on the LCD by pressing the HOLD button.

ZERO Adjustment

Removing small offsets caused by environmental changes by zeroing the meter.

Max-Min Reading Record

Recording and recalling the highest (MAX) and lowest (MIN) readings.

Setup Mode

Accessing the Setup mode

Steps to enter and navigate the meter's setup menu.

Setting the Clock Time

Instructions for setting the meter's internal clock and date.

Setting the Datalogger Sampling Time (Rate)

Configuring the interval at which data is logged to the SD card.

Auto Power OFF Feature

Numerical Format Configuration

SD Card Formatting

System Reset Procedure

Datalogging

Types of Data Recording

Manual logging up to 99 readings and automatic logging based on sampling rate.

SD Card Information

Inserting, formatting, and setting the clock for the SD card.

Manual Datalogging

Step-by-step guide to manually logging readings onto the SD card.

Automatic Datalogging

Pause/Resume Logging

Temporarily pausing and resuming the automatic data logging process.

Data Storage Structure

How data is organized into folders and spreadsheet documents on the SD card.

SD Data Card to PC Data Transfer

Data Transfer Steps

Instructions for removing the SD card and transferring data to a PC.

RS-232/USB PC Interface

AC Power Adaptor

Battery Replacement and Disposal

Specifications

Display

Details about the backlit LCD display and its size.

Status Indicators

Overview of status indicators like over-range beep and low battery icon.

Datalogger Sampling Rate

Specifies the sampling rates for AUTO and MANUAL logging.

Memory Card

Information about the supported SD memory card size.

Data Hold

Functionality to freeze the displayed reading.

Memory Recall

Capability to record and recall maximum and minimum readings.

Data Output

Details the RS-232 / USB PC computer interface for data output.

Operating Temperature

Specifies the operational temperature range of the meter.

Operating Humidity

Indicates the maximum operating relative humidity.

Auto Power OFF

Details the auto power off feature and its inactivity timer.

Power Supply

Information on battery power and optional AC adaptor.

Power Consumption

Details power consumption in various operating modes.

Weight

Specifies the weight of the meter with and without batteries.

Dimensions

Provides meter and sensor dimensions.

Electrical Specifications

Acceleration

Electrical specifications for Acceleration measurement (range and accuracy).

Velocity

Electrical specifications for Velocity measurement (range and accuracy).

Displacement

Electrical specifications for Displacement measurement (range and accuracy).