Table 39: Power Specications (AC Power Supplies) (continued)
Power supply cord gauge 18 AWG (0.75 mm
2
) up to 6 feet or 2 meters
or
16 AWG (1.0 mm
2
) over 6 feet
Efciency 94% at 50% load and 91% at 100% load
Table 40: Power Specications (DC Power Supplies)
Nominal input -48VDC, 21A
DC Voltage input range -48 VDC
Inrush Current 21 A peak
Wire size 14 AWG (1.5 mm2 copper stranded).
DC Output +12VDC, 65A; +12Vsd, 2.1A
Power (W) 800 W
Table 41: Environmental Specications (All Power Supply Units)
Operating temperature 0°C to 55°C (normal operation)
Storage temperature -40°C to 70°C
Operating humidity 5% to 90% relative humidity, non-condensing
Operational shock 10 G, 4.3 m/s
Power Cord Requirements for AC-Powered Switches and AC Power
Supplies
An AC power cord is not included with the AC power supply.
Power cords used with AC-powered switches or AC power supplies must meet the
following requirements:
The power cord must be agency-certied for the country of use.
The power cord must have an IEC320-C13 connector for connection to the switch or
power supply.
The power cord must have an appropriately rated and approved wall plug applicable
to the country of installation.
For cords up to 6 feet (2 m) long, the wire size must be 18 AWG (.75 mm
2
) minimum;
over 6 feet, the minimum wire size is 16 AWG (1.0 mm
2
).
For details about obtaining AC power cords for use in your country, refer to http://
www.extremenetworks.com/product/powercords/.