Summit WM Technical Reference Guide, Software Version 5.1 71
Error LED
Failed to identify FDD. Possibly
due to removal of FDD card.
Activity LED = Enabled
Warning LED = Enabled
Error LED = Enabled
SSD= 1
Re-insert card. If card
present, contact
Technical Support to
arrange replacement.
Failed to initialize NPE card.
Activity LED = Enabled
Warning LED = Enabled
Error LED = Enabled
SSD= 2
Re-insert card. If card
present, contact
Technical Support to
arrange replacement.
Critical threshold reached (95C
for NPE). System will reboot.
Activity LED = Enabled
Warning LED = Enabled
Error LED = Enabled
SSD= 3
Check speed/state for
fans. Check for proper
airflow access. If
problem persists,
contact Technical
Support.
Full fan assembly failure (both
trays). System will reboot.
Activity LED = Enabled
Warning LED = Enabled
Error LED = Enabled
SSD= 4
Re-insert fan tray. If
card present, contact
Technical Support to
arrange replacement.
Application initialization failure.
Startup manager failed to
initialize all of system’s
components. system will
reboot.
Activity LED = Enabled
Warning LED = Enabled
Error LED = Enabled
SSD= 5
If problem persists,
contact Technical
Support.
Lost connectivity with FE.
Possible failure of NPE card.
System will reboot.
Activity LED = Enabled
Warning LED = Enabled
Error LED = Enabled
SSD= 6
Investigate failure
condition in
/var/controller/
log/logs/
ixcapture.log
If problem persists,
contact Technical
Support.
Table 19: Summit WM Controller WM200/2000 application states (Continued)
Condition
Log
Level
Comment Action

Table of Contents

Other manuals for Extreme Networks Summit WM