EasyManua.ls Logo

Extron electronics IPCP Pro Series - Cabling and Features

Extron electronics IPCP Pro Series
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
IPCP Pro Series • Setup Guide (Continued)
Cabling and Features
Attach cables using the following wiring diagrams as a guide. Full details are available in the IPCPPro Series User Guide.
ATTENTION:
Installation and service must be performed by experienced personnel.
L’installation et l’entretien doivent être effectués par du personnel expérimenté.
Power Input — External
POWER
12V
x.xA MAX
R
Ground all devices.
External
12 VDC
Power Supply
+12 VDC input
– Return
Ridged
Smooth
To
AC
power
Front Panel
Power Input, External Power Supply
Front panel LED ( ) blinks during
boot-up and remains lit when the
IPCP is powered and operational.
Connect to
included 12 VDC
power supply.
NOTE:
Check the polarity of the power
supply before connecting it to the IPCP.
Ridged
Smooth
Tie Wrap
3/16"
(5 mm)
Max.
Power Input — Internal
R
1.2A MAX
100-240V 50-60Hz
Power Input, Internal Power Supply
Front panel LED ( ) blinks
during boot-up and remains lit
when the IPCP receives power.
Connect to 100 to
240 VAC.
Rear
Panel
Front Panel
Power Output — Switched 12 VDC Power Output
21
LIMIT
SWITCHED
12 VDC
OVER
43
12 VDC
SWITCHED 12 VDC
40W MAX TOTAL
3 4
1 2
Lights if total power drawn
is 41-46 watts.
Lights if total power drawn
exceeds 47 watts.
Power output shuts off
until the user corrects the
overload.
Switched 12 VDC
Power Output
Total output for all four ports
combined:
12 VDC, 40 watts (max.)
Corresponding front panel
green LEDs ( ) light when
power is available at each port.
3/16"
(5 mm)
Max.
Rear
Panel
Front
Panel
Tie Wrap
Power Output — PoE+
The IPCPPro360 can output PoE+ on AV LAN ports 2 and 3. For details, see the PoE+ output information on page 11.
ATTENTION:
Always use a power
supply supplied or
specified by Extron. Use
of an unauthorized power
supply voids all regulatory
compliance certification and
may cause damage to the
supply and the unit.
Utilisez toujours une source
d’alimentation fournie par
Extron. L’utilisation d’une
source d’alimentation non
autorisée annule toute
certification de conformité
réglementaire et peut
endommager la source
d’alimentation que l’unité.
Rev. E: replaced
isometric power
supply with
orthogonal version.
Updated French
translation of 2nd
paragraph.