EasyManuals Logo

F.W. Bell 8000 series User Manual

F.W. Bell 8000 series
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
F.W. BELL 8000 Series Gauss/Tesla Meter Instruction Manual
Section 8 – Remote Operation 8-26
Table 8-12 SCPI Zeroing Commands
COMMAND DESCRIPTION
:CALibration#:ZERo:HSENsor:INITiate Zero the Hall probe and instrument for single channel
:CALibration#:ZERo:HSENsor:MODe <n> Set the auto zero mode
:CALibration#:ZERo:HSENsor:MODe? Query the auto zero mode
:CALibration:ALL:ZERo:HSENsor:INITiate Zero the Hall probe and instrument for all channels
:CALibration:ALL:ZERo:HSENsor:MODe <n> Set the auto zero mode for all channels
Table 8-13 SCPI Relative Offset Commands
COMMAND DESCRIPTION
:INPut#:OFFSet <NRf> Set relative offset value
:INPut#:OFFSet? Query relative offset value
:INPut#:OFFSet:STATe <b>|ONCe Enable/disable the relative offset function
:INPut#:OFFSet:STATe? Query state of relative offset function
Table 8-14 SCPI Analog Output Commands
COMMAND DESCRIPTION
:OUTPut#:UNCorrected:MODe <n> Set the output mode of the uncorrected analog output
:OUTPut#:UNCorrected:MODe? Query the output mode of the uncorrected analog output
:OUTPut#:UNCorrected:SCALing <n> Set the scaling of the uncorrected analog output
:OUTPut#:UNCorrected:SCALing? Query the scaling of the uncorrected analog output
:OUTPut#:CORRected:MODe <n> Set the output mode of the corrected analog output
:OUTPut#:CORRected:MODe? Query the output mode of the corrected analog output
:OUTPut#:CORRected:SCALing <n> Set the scaling of the corrected analog output
:OUTPut#:CORRected:SCALing? Query the scaling of the corrected analog output
:OUTPut:VECTorsum:MODe <n> Set the output mode of the vector sum analog output
:OUTPut:VECTorsum:MODe? Query the output mode of the vector sum analog output
:OUTPut:VECTorsum:SCALing <n> Set the scaling of the vector sum analog output
:OUTPut:VECTorsum:SCALing? Query the scaling of the vector sum analog output
Table 8-15 SCPI Vector Summation Command
COMMAND DESCRIPTION
:CALCulate:VSUMmation? Query vector summation result and angles (8030 only)
Table 8-16 SCPI Hold Commands
COMMAND DESCRIPTION
:CALCulate#:HOLD:MINimum:STATe <b> Enable/disable the MIN HOLD function
:CALCulate#:HOLD:MINimum:STATe? Query the state of the MIN HOLD function
:CALCulate#:HOLD:MINimum:CLEar Resets the value being held by the MIN HOLD function
:CALCulate#:HOLD:MINimum? Query the value being held by the MIN HOLD function
:CALCulate#:HOLD:MAXimum:STATe <b> Enable/disable the MAX HOLD function
:CALCulate#:HOLD:MAXimum:STATe? Query the state of the MAX HOLD function
:CALCulate#:HOLD:MAXimum:CLEar Resets the value being held by the MAX HOLD function
:CALCulate#:HOLD:MAXimum? Query the value being held by the MAX HOLD function
:CALCulate#:HOLD:PEAK:STATe <b> Enable/disable the PEAK HOLD function
:CALCulate#:HOLD:PEAK:STATe? Query the state of the PEAK HOLD function
:CALCulate#:HOLD:PEAK:CLEar Resets the value being held by the PEAK HOLD function
:CALCulate#:HOLD:PEAK? Query the value being held by the PEAK HOLD function

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the F.W. Bell 8000 series and is the answer not in the manual?

F.W. Bell 8000 series Specifications

General IconGeneral
BrandF.W. Bell
Model8000 series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals