EasyManua.ls Logo

FAAC 402 - 2.5. By-Pass Valves Adjustment; 3. Manual Operation; 4. Maintenance

FAAC 402
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
1 in
3/16
Fig. 15
3. MANUAL OPERATION
If the gate must be moved manually due to a power outage or
other failures use the manual release device as follows:
- Insert the triangular key on the release screw located in the lower
part of the flange (Fig.15).
- Turn the release key counter-clockwise for about two turns.
- Open or close the leaf manually.
To re-lock the operator turn the key clockwise until it stops.
4. MAINTENANCE
Run a functional check of the system at least every 6 months.
Pay special attention to the efficiency of the safety and release
devices (Including the thrust force of the operator), and the
perfect operation of the gate hinges.
Checking oil level:
Periodically check the oil level inside the tank
Cut power to the system.
Position the operator vertically, with the rear flange high up.
Remove the oil filling plug.
Insert a screwdriver until it comes into contact with the electric motor
as shown in Fig. 16.
Remove the screwdriver and check oil level as shown in Fig. 16.
USE ONLY FAAC HP FLUID OIL
Periodically check the correct adjustment of the anti-crushing
safety device (BY-PASS) and the efficiency of the release system
to allow manual operation.
The safety devices installed on the system must be checked
every 6 months.
Fig. 16
REPAIRS
For any repairs, contact FAAC’s authorised Repair Centers.
UNLOCK
LOCK
Fig. 14
The 402 operator has an anti-crushing safety device which limits
the operator’s force if an obstacle is encountered while the gate
is moving.
To adjust the intervention threshold of the anti-crushing system,
turn the By-Pass screws on the flange (Fig.14).
OPEN screw (green) : gate opening direction.
CLOSE screw (red) : gate closing direction.
(the opposite applies in case of outward opening)
To reduce pressure, turn the screws anti-clockwise.
To increase pressure, turn the screws clockwise.
After the adjustment is complete attach the protective plastic
cover over the by-pass screws using the supplied self tapping
screws.
2.5. BY-PASS VALVES ADJUSTMENT

Other manuals for FAAC 402