6. MANUAL OPERATION
If the automated system needs to be moved manually due to a power lack or to an operator malfunction, proceed as follows:
1) Cut power by means of the safety circuit breaker (even in the event of a power lack).
2) Slide the protective cap, Fig.26/1.
3) Insert the key and turn it 90°, Fig.26/2.
4) To release the operator turn 180° the control lever to the direction indicated by the arrow on the release system, Fig.26/3.
5) Open and close the leaf manually.
Note: To hold the operator in manual operation the release device should be left in its current positions and the system
should be without power.
6.1. Restoring normal operation
To restore normal operating conditions, proceed as follows:
1) Turn the release system 180° in the opposite direction of the arrow.
2) Turn 90° the release key and remove it.
3) Close the protection cover.
4) Power up the system and perform some movements in order to check the correct restoring of every function of the automated
system.
7. MAINTENANCE
To censure trouble-free operation and a constant safety level, an overall check of the system should be carried out every 6 months.
A form for recording operations has been included in the “User’s Guide” booklet.
8. REPAIRS
For any repairs, contact the authorised Repair Centres.
9. AVAILABLE ACCESSORIES
Refer to catalogue for available accessories.
10. SPECIAL APPLICATIONS
There is no special application other than the described use.