EasyManua.ls Logo

FAAC 540 BPR - Warnings; Technical Specifications; Layout and Components; Description of Components

FAAC 540 BPR
24 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
M
C
24 V
24 V
24 V
24 V
123456
1 2 3 4 5 6
Power supply voltage 230Vac (+6% -10%) - 50Hz
Absorbed power 4 W
Motor max. load 800 VA
Accessories max. current 200 mA
Operating ambient temperature
-20°C to +55°C
Fuses
F1 = 6.3A-250V
F2 = self-resetting
Function logics
B/C, B, C, EP, AP, P
default = B/C
Work time (time-out)
Self-learning (0-10 min in 2.5 sec steps)
default = 10 min
Pause time
Self-learning
(0-5 min in 1.5 sec steps)
default = 30 sec
Terminal board inputs
Open, Close, Stop,
Limit-switch, CL safety
devices, Power supply
Terminal board outputs
Motor and power supply
to accessories
Programmable functions Logic
Learning functions Work time, Pause time
2. TECHNICAL SPECIFICATIONS
4. CONNECTIONS
Description of components
J1 inputs terminal board and power supply to accessories
J2 connector for radio receiver (see Note)
J3 (not used)
J4 motor terminal board
JS 230 Vac power supply terminal board
J6 limit-switch terminal board
LED Signalling LEDs
SW1 programming key
TR1 transformer
F1 6.3A- 250 V (motor protection)
F2 self-resetting (accessories protection)
1. WARNINGS
Before attempting any work on the electronic equipment
(connections, maintenance), always turn off power
- Install, upstream of the system, a differential thermal breaker
with adequate tripping threshold.
- Always separate power cables from control and safety cables
(push-button, receiver, photocells, etc.). To avoid any electrical
disturbance, use separate sheaths or a screened cable (with
the screen earthed).
An RP2 type 2-channel receiver can be connected to the J2
connector, so that the OPEN and CLOSE facilities of the automated
system can be commanded directly with a 2-channel radio control.
If using a single-channel RP type receiver, only OPEN can be commanded.
3. LAYOUT AND COMPONENTS
Terminal Description Device connected
1 OPEN
Device with N.O. contact
(see chap. FUNCTION LOGICS)
2 CLOSE
Device with N.O. contact
(see chap. FUNCTION LOGICS)
3 STOP
Device with N.C. contact
which causes the automated
system to lock
4
- 24Vdc
Power supply for accessories
5
+ 24Vdc
6
SAFETY
Closure safety device with
N.C. contact (see chap.
FUNCTION LOGICS)
7 COM
Limit switch common contact
8FCA
Opening limit-switch
(N.C. contact)
9 FCC
Closure limit-switch
(N.C. contact)
10 COM
Motor common contact
11 CL
Motor closure stage
12 OP
Motor opening stage
13 - 14
230 Vac - 50Hz
Board power supply
E. g.: a connection with 2 pairs of closure photocells and a safety
device with NC contact.
Other safety device
Description of terminal boards
BLUE
Fig. 1
Fig. 2
CONTROL UNIT 540 BPR