4.5. ADJUSTING THE COUNTERWEIGHTS
The weight of the counterweights must be increased to
ensure smooth operation. If there is insufficient space to
add to the existing counterweights, remove them and
replace them with blocks of a higher specific weight. To
adjust the weights, release the operator and move the
door to half-open position (45°). The door should remain in
balance.
4.6. DOUBLE APPLICATION
For garage doors 3.50 to 5 m wide, one 595 I (integrated)
operator and one 595 S (slave) operator must be used. The
maximum permitted height is 3 m. Install in the same way as
for a single motor (fig. 9). After completing mechanical
installation make the electrical connections shown in fig.
20.
5. 596 MPS ELECTRONIC CONTROL UNIT
5.1. CONNECTING ELECTRONIC CONTROL UNIT
Caution: Before touching the electronic unit (connections,
programming, maintenance) always switch off the power
supply.
Observe points 10, 11, 12, 13, 14 of GENERAL SAFETY
REQUIREMENTS.
LAYOUT AND ELECTRICAL WIRING
Fig. 19
a
DS1
J4
TF1
654321
87654321 9
16151413121110
1817 19
J3
F2
F1
J1
J2
J9
b
d
e
c
f
g
Prepare the conduits and make the electrical connections
between the 596 electronic control unit and the chosen
accessories as shown in Fig. 17.
a J1 Terminal block: low voltage (fig. 19) used to connect
all accessories (see table 3).
1- Open command (N.O.): any device (button,
photocell, detector, etc.) which can give an
opening and/or closure pulse to the door by closing
a contact.
To install more than one opening activating device
connect the N.O. contacts in parallel.
2 - Safety devices
Any device (photocells, sensitive edges, magnetic
loops) with an N.C. contact that activates when
there is an obstacle present in the area protected
by the safety devices and stops the movement of
the door.
To install more than one safety device connect the
N.C. contacts in series.
N.B.: If safety devices are not connected, jumper
terminals 2 and 4.
Table 2: 596 MPS Control unit technical specifications
Power supply 230 V(+6%-10%) - 50 Hz
Absorbed power 10 W
Max. motor load 800 W
Max. accessories load 0.250 A
Temperature range -20 °C +55 °C
Fuses N. 2 (see fig.19)
Operations logics Automatic / Semi-automatic
Opening/closure time Selectable via dip-switch (from 25 to 40 s)
Pause time Selectable via dip-switch (30 or 60 s)
Terminal block inputs Open/Stop /Closing safeties / mains power +earth
Terminal block outputs Motor - Accessories 24 Vdc power supply -
Starting capacitor - Courtesy lamp 230 Vac
Quick connector Decoder cards - RP SL/DS receiver
Microswitch-selectable functions Operating logics - Fail-safe -
Op/Cl times - Pause time -
Closure safety operating logic
FSW
230Vac
+6% - 10%
C
C
TX
RX
2
1
4
3
2
1
5
BLUE
24 Vdc
ST
OP
FSW
OPEN
87654321 9
16151413121110
1817 19
F
AIL-SAFE
FCC
SERVICE LIGHT
MAX 40 W
FCA
J1
J2
J9
Fig. 20