Tab. 3/d
LOGIC “E” PULSES
GATE STATUS OPEN-A OPEN-B STOP OPENING SAFETY DEVICES CLOSING SAFETY DEVICES OP/CLOS. SAFETY DEVICE EDGE SAFETY DEVICE
CLOSED Opens the leaf
Opens the leaf for partial
opening time
No effect (OPEN disabled) No effect No effect (OPEN disabled)
OPEN Re-closes the leaf immediately
Stops operation
No effect No effect (OPEN disabled)
ON CLOSING Re-opens the leaf immediately No effect (saves OPEN) see paragraph 5.2.
Stops and, on release, rever-
ses on opening
Reverses on opening for 2”
ON OPENING Stops operation see paragraph 5.2. No effect
Stops and, on release, conti-
nues opening
Reverses on closing for 2”
STOPPED
Closes the leaf (with the Closing safety devices engaged, it
opens at the 2
nd
pulse)
No effect (OPEN disabled) No effect No effect (OPEN disabled)
Tab. 3/e
LOGIC “”EP”” PULSES
GATE STATUS OPEN-A OPEN-B STOP OPENING SAFETY DEVICES CLOSING SAFETY DEVICES OP/CLOS. SAFETY DEVICE EDGE SAFETY DEVICE
CLOSED Opens the leaf
Opens the leaf for partial
opening time
No effect (OPEN disabled) No effect No effect (OPEN disabled)
OPEN Re-closes the leaf immediately
Stops operation
No effect No effect (OPEN disabled)
ON CLOSING
Stops operation
No effect (saves OPEN) see paragraph 5.2.
Stops and, on release, rever-
ses on opening
Reverses on opening for 2”
ON OPENING see paragraph 5.2. No effect
Stops and, on release, conti-
nues opening
Reverses on closing for 2”
STOPPED
Restarts movement in reverse direction (always closes after
a Stop)
No effect (OPEN disabled)
No effect (if it must open, it
disables OPEN)
No effect (if it must close, it
disables OPEN)
No effect (OPEN disabled)
Tab. 3/f
LOGIC “C” CONTROLS ALWAYS HELD DOWN PULSES
GATE STATUS OPEN-A (opening) OPEN-B (closing) STOP OPENING SAFETY DEVICES CLOSING SAFETY DEVICES OP/CLOS. SAFETY DEVICE EDGE SAFETY DEVICE
CLOSED Opens the leaf No effect No effect (OPEN-A disabled)
No effect (OPEN-B disabled)
No effect (OPEN-A disabled)
No effect (OPEN-A/B disabled)
OPEN No effect Closes the leaf No effect (OPEN-B disabled) No effect (OPEN-A disabled) No effect (OPEN-B disabled)
ON CLOSING Stops operation
Stops operation
No effect
Stops operation (OPEN-B
disabled)
Stops operation (OPEN-A/B
disabled)
Reverses on opening for 2”
ON OPENING Stops operation
Stops operation (OPEN-A
disabled)
No effect
Reverses on closing for 2”