8
Fig. 23b
A2, E2 and S2 logics interrupting the safety device contacts
causes the gate to stop closing, then to start opening again
when the safety devices are released.
5.2.10. ELECTRONIC SAFETY DEVICE
(models 820 EMC - 860 EMC only)
The operator is equipped with a system which cuts in when
it senses a 20% reduction in pinion speed. The device inverts
the closing movement and inhibits opening movement.
When this safety device cuts in, LED S goes out for a few
seconds. Automatic re-closure is inhibited if the electronic
anti-crushing safety has cut in.
5.3. DIPSWITCH SETTINGS
N.B.: PRESS THE RESET BUTTON AFTER ALL PROGRAMMING
OPERATIONS
5.4. OPERATION IN VARIOUS LOGICS
TABLE 5 LOGIC E1 (SEMIAUTOMATIC)
SAFETY
no effect
no effect
inverts motion
no effect
no effect
GATE STATUS
CLOSED
OPEN
CLOSING
OPENING
STOPPED
OPEN - A/C (1) -
opens (2)
recloses (2
inverts motion
stops
recloses (reopens when safety
devices are engaged) (2)
STOP
no effect
no effect
stops
stops
no effect
IMPULSES
LOGIC E1
GATE STATUS
CLOSED
OPEN
CLOSING
OPENING
STOPPED
OPEN -A/C(1)-
opens (2)
recloses (2)
inverts motion
stops
recloses (reopens when
safety devices are
engaged) (2)
STOP
no effect
no effect
stops
stops
no effect
LOGIC E2
SAFETY
no effect
no effect
stops and inverts motion
when disengaged (2)
no effect
no effect
IMPULSES
IMPULSES
LOGIC A1
SAFETY
no effect
freezes pause until
disengagement
inverts motion
no effect
no effect
STOP
no effect
stops counting
stops
stops
no effect
GATE STATUS
CLOSED
OPEN
CLOSING
OPENING
STOPPED
OPEN - A/C (1) -
opens and recloses after
pause time (2)
recloses after 5 s (3)
inverts motion
no effect
recloses (2)
TABLE 7 LOGIC A1 (AUTOMATIC)
IMPULSES
LOGIC A2
GATE STATUS
CLOSED
OPEN
CLOSING
OPENING
STOPPED
OPEN - A/C (1) -
opens and recloses after
pause time (2)
recloses after 5 s (3)
inverts motion
no effect
recloses (2)
STOP
no effect
stops counting
stops
stops
no effect
SAFETY
no effect
recloses after 5 s
stops and inverts motion
when disengaged (2)
no effect
no effect
TABLE 8 LOGIC A2 (AUTOMATIC)
LOGIC S1
IMPULSES
GATE STATUS
CLOSED
OPEN
CLOSING
OPENING
STOPPED
OPEN - A/C (1) -
opens and recloses after
pause time (2)
recloses immediately
(2 and 3)
inverts motion
inverts motion
recloses (2)
STOP
no effect
stops counting
stops
stops
no effect
SAFETY
no effect
recloses after 5 s
inverts motion
no effect
no effect
TABLE 9 LOGIC S1 (SAFETY)
LOGIC S2
IMPULSES
STOP
no effect
stops counting
stops
stops
no effect
GATE STATUS
CLOSED
OPEN
CLOSING
OPENING
STOPPED
OPEN - A/C (1) -
opens and recloses after
pause time (2)
recloses immediately
(2 and 3)
inverts motion
inverts motion
recloses (2)
SAFETY
no effect
freezes pause until
disengagement
stops and inverts motion
when disengaged (2)
no effect
no effect
TABLE 10 LOGIC S2 (SAFETY)
GATE STATUS
CLOSED
OPEN
CLOSING
OPENING
STOPPED
LOGIC B IMPULSES
OPEN
opening (2)
no effect
no effect
no effect
completes
opening (2)
A/C (5)
no effect
closing (2)
no effect
no effect
completes
opening (2)
SAFETY (until
disengagement)
no effect
inhibits closing
stops
no effect
inhibits closing
STOP
no effect
no effect
stops movement
stops movement
no effect
TABLE 11 LOGIC B (SEMIAUTOMATIC)
TABLE 6 LOGIC E2 (SEMIAUTOMATIC)
12345678
Logic SW1 SW2 SW3
E1 ON ON ON
A1 OFF ON ON
S2 ON OFF ON
S1 OFF OFF ON
BONONOFF
COFFONOFF
E2 ON OFF OFF
A2 OFF OFF OFF
Pause time (sec) (1)
Logic
A1 A2 S2 S1 SW4 SW5
515ONON
10 30 OFF ON
30 60 ON OFF
120 180 OFF OFF
Gate closure direction as viewed from inside SW8
To right ON
To left OFF
Pre-flashing (2) SW7
Yes ON
No OFF
Warning light operation (3)
Gate status
SW6
Closed
Opening/Open Closing
ON
OFF
Steady light
Flashing
Off
Steady light
(1) Pause times include pre-flashing.
(2) Pre-flashing commences 5 seconds before the start of each
movement.
(3) Warning light connected between 8 and 9 (if connected
between 8 and 10, operation is inverted).
Fig. 24