To use the FAIL-SAFE mode connect the negative power supply of the transmitters to OUT (pin 9), and set dip-
switch 11 and 12 to ON on DS1
Connection of a pair of closing photocells and a pair of opening photocells
Fig. 12
Connection of a generic closing safety device and a generic
open safety device
Connection of no safety or stop devices (NOT RECOMMENDED) Connection of one pair of opening photocells
Other optional safety devices
to connect in series
Fig. 13
Fig. 14
Fig. 15
To use the FAIL-SAFE mode connect the nega-
tive power supply of the transmitters to OUT
(pin 9), and set dip-switch 11 and 12 to ON
on DS1
When using the FAIL-SAFE mode also the
safety inputs not used (FSW CL , FSW OP)
must be connected to OUT (pin No. 9
RX= Photocell Receiver
TX= Ptotocell Transmitter
CL= Closing
OP= Opening