7
SETTING
+
DL 1
DL 2
DL 3
DL 4
DL 5
J2 4
6
5 PROGRAMMING
TR 3 – SPEED ADJUSTMENT FOR MOTOR1 AND MOTOR 2
Turn clockwise to increase the opening and closing speed
TR 4 – SENSITIVITY ADJUSTEMENT FOR OBSTACLE DETECTION FOR MOTOR 1 AND MOTOR 2
Turn clockwise to increase the sensitivity for obstacle detection.
With this trimmer you can adjust the reaction time for the board to invert the motion of the gate in case of
obstacle detection, or the complete stop in case the board is in the positive stop detection zone
IF SW 11=OFF and SW 12 = OFF on DS1
- In a logic with pause time the rst time an obstacle is detected during close the gate will reopen and stay open
Until a new impulse is given. If, during the next cycle and obstacle is detected again then the board will go
in alarm mode and won’t take any more command until the power is cycled (See Obstacle Alarm on page xx)
OTHERWISE
- The third time an obstacle is detected in the same direction it will be considered as positive stop and the
gate will be stopped in that position
TR 5 – PAUSE TIME ADJUSTMENT ( 0 - 4 min. )
Turn clockwise to increase the pause time.
TR6 - ADJUSTMENT OF THE START TIME DELAY IN CLOSING OF LEAF 1 OVER LEAF 2 ( 0 - 15 sec )
Turn clockwise to increase the delay
5.1 ADJUSTING TRIMMERS
TR1 – FORCE ADJUSTMENT MOTOR 1
Turn clockwise to increase the opening and closing force
1 min
2 min
3 min
4 min0 sec
30 sec
TR 2 – FORCE ADJUSTEMENT MOTOR 2
Turn clockwise to increase the opening and closing force