Tab. 5
Tab. 6
11 LOGIC TABLES
LOGIC “A PULSES
STATUS OF AUTOMATED
SYSTEM
OPEN A OPEN B STOP FSW-OP FSW-CL FSW-OP/CL
FSW-OPEN
CLOSED
opens leaves and
closes after pause
time
opens leaf 1 and
closes after pause
time
no effect (opening
inhibited)
no effect (opening
inhibited)
no effect
no effect (opening
inhibited)
opens leaves and
closes after pause
time
OPENING no effect stops operation
reverses immediately
at closing
no effect
stops and continues
to open at
disengagement
no effect (1)
OPEN IN PAUSE recharge the pause time stops operation no effect
recharges pause
time
(closing inhibited)
recharges pause
time
(closing inhibited)
recharges pause
time
(closing inhibited) (1)
CLOSING
reverses immediately
at opening
reverses immediately
at opening
stops operation no effect
reverses immediately
at opening
stops and, at
disengagement,
reverses at opening
reverses immediately
at opening
STOPPED closes closes
no effect (opening
and closing inhibited)
no effect (opening
inhibited)
no effect (closing
inhibited)
no effect (opening
and closing inhibited)
opens leaves
LOGIC “EP PULSES
STATUS OF AUTOMATED
SYSTEM
OPEN A OPEN B STOP FSW-OP FSW-CL FSW-OP/CL FSW-OPEN
CLOSED
opens leaves opens leaf 1
no effect (opening
inhibited)
no effect (opening
inhibited)
no effect
no effect (opening
inhibited)
opens leaves
OPENING stops operation (1) stops operation stops operation
reverses immediately
at closing
no effect
stops and continues
to open at
disengagement
no effect (1)
OPEN closes closes
no effect (closing
inhibited)
no effect
no effect (closing
inhibited)
no effect (closing
inhibited)
no effect (1)
CLOSING stops operation stops operation stops operation no effect
reverses immediately
at opening
stops and, at
disengagement,
reverses at opening
reverses immediately
at opening
STOPPED
After OPEN: Restarts moving in reverse
direction
After STOP: Re-closes the leaf/ves
immediately
(1)
no effect (opening
and closing inhibited)
no effect (opening
inhibited)
no effect (closing
inhibited)
no effect (opening
and closing inhibited)
opens leaves
(1) If the cycle began with OPEN-B (partial opening), an OPEN-A pulse will activate both leaves to open.