E045 36 732786 - Rev.C
ENGLISH
Display Function
Default
Uc
BOARD CONFIGURATION UPGRADE:
This function lets you transfer the configuration to the board (file E045.prg).
If + and - are pressed simultaneously for at least 5 seconds, you will access
the board configuration update. The writing
no will disappear and, in its place,
the writing
-- and the USB DL10 LED will begin flashing.
Once updating is completed,
Y will be displayed if it has been done correctly,
otherwise the writing
no will appear again.
The upgrade is carried out correctly only if the USB memory
contains a valid file named exactly
E045.prg
--
Ur
RADIO CODE LIST UPGRADE:
This function lets you update the radio code list on the board (file
E045.rad).
If + and - are pressed simultaneously for at least 5 seconds, you will access
the board update. The writing
no will disappear and, in its place, the writing
-- and the USB DL10 LED will begin flashing.
Once updating is completed
Y will be displayed if it has been done correctly,
otherwise the writing
no will appear again.
The upgrade is carried out correctly only if the USB memory
contains a valid file named exactly
E045.rad
--
dc
BOARD CONFIGURATION DOWNLOAD:
This function lets you save the board configuration in the USB memory in order
to store (parameter
01) or copy the configuration to other systems (parameter
00).
If + and – are pressed simultaneously for at least 5 seconds, the following
selection values will appear:
01 = Storage: the configuration file will be saved in the format E045_xxx.prg
where xxx=000/001/002 etc. depending on how many configuration files there
are in the USB memory.
00 = Copy: the configuration file will be saved in the format E045.prg by
overwriting any other configuration file present with the same name, so it can
be used to upgrade another system.
Press + and - to select the desired parameter and, by pressing F, the board
will proceed to save the file and display
Y when done correctly, or no in case
of errors during saving.
--