E045 42 732786 - Rev.C
ENGLISH
1
if the cycle began with OPEN-B, opens totally
2
operation can be modified by programming
DEAD-MAN LOGIC (OPEN-B INPUTS BECOME CLOSE)
DEAD-MAN COMMANDS PULSES
AUTOMATED
SYSTEM
STATUS
OPEN
A OPEN B CLOSE STOP FSW OP FSW CL FSW CL/OP
CLOSED OPENS NO
EFFECT
NO
EFFECT
(OPEN DISABLED)
NO EFFECT
NO
EFFECT
(
OPEN DISABLED)
OPENING NO EFFECT CLOSES STOPS* REVERSES NO EFFECT
STOPS
; CLOSES AT
RELEASE
(
SAVES OPEN/CLOSE)
OPEN NO EFFECT CLOSES
NO
EFFECT
(
OPEN/CLOSE
DISABLED)
NO EFFECT
NO
EFFECT
(
CLOSE
DISABLED)
NO EFFECT (OPEN/
CLOSE DISABLED)
CLOSING OPENS NO EFFECT STOPS* NO EFFECT
REVERSES
2
STOPS; OPENS AT
RELEASE (SAVES
OPEN/CLOSE)
*
STOPPED OPENS CLOSES
NO
EFFECT
(
OPEN/CLOSE
DISABLED)
NO EFFECT
(
OPEN
DISABLED)
NO EFFECT
(
CLOSE
DISABLED)
NO EFFECT (OPEN/
CLOSE DISABLED)