3.1 BASIC PROGRAMMING
Basic Function Default
CF
MOTOR TYPE:
1 Motors for swing gates
2 Motors for sliding gates
PC Mixed configuration from a PC/MAC
(e.g.: one swing and one slide)
dF
DEFAULT:
Y Indicates that all the set values are
default values.
no Indicates that at last 1 set value is
different from the default values.
Select
Y if you wish to restore the default
configuration.
Y
LO
OPERATING LOGIC:
E, EP, S, SA, SP, A1, A, AP, At,
b, bC, C, CU
Refer to the specific paragraph for a description
of the operating logics.
E
PA
PAUSE A TIME (only displayed with Auto-
matic logic):
Can be adjusted from
00 to 9.5 minutes.
30
Pb
PAUSE B TIME (only displayed with Auto-
matic logic):
Can be adjusted from
00 to 9.5 minutes.
30
Mn
NUMBER OF MOTORS:
1 = 1 motor
2 = 2 motors
2 (swing)
1 (sliding)
F1
MOTOR 1 POWER:
01 = minimum power
50 = maximum power
25
F2
MOTOR 2 POWER (only displayed with the
Mn = 2 function):
01 = minimum power
50 = maximum power
25
En
ENCODER USE:
Y = encoders on both motors
no = disabled encoders
no
FA
LIMIT SWITCH WHEN OPENING (only
displayed with the
CF = 1 or CF = PC
function):
no = opening limit switches disabled
01 = the limit switch determines when the
movement is stopped
02 = the limit switch determines when
deceleration begins
no
Basic Function Default
FC
LIMIT SWITCH WHEN CLOSING (only displa-
yed with the
CF = 1 or CF = PC function):
no = closing limit switches disabled
01 = the limit switch determines when the
movement is stopped
02 = the limit switch determines when
deceleration begins
no
Br
SLIDING LEAF BRAKING (only displayed
with the
CF = 2 or CF = PC function):
00 = braking disabled
10 = maximum braking time
05
Cd
LEAF CLOSING DELAY (only displayed with
the
Mn = 2 function):
Can be adjusted from
00 to 3 minutes.
05
bu
BUS-2easy DEVICE REGISTRATION:
Register: keep
and
-
pressed simulta-
neously for at least 5 s (the display flashes
during this time).
Y will appear once confirmation of the com-
pleted registration is given.
Release
and
-
. The status of the BUS-2easy
devices will appear on the display.
no
M2
MOTOR 2 dead-man DRIVE mode (only
displayed with the
Mn = 2 function):
+/
R1
OPENS (displaying
oP) for as long as
the button is pressed
-/
R2
CLOSES (displaying cL) for as long as
the button is pressed
--
M1
MOTOR 1 dead-man DRIVE mode:
+/
R1
OPENS (displaying
oP) for as long as
the button is pressed
-/
R2
CLOSES (displaying cL) for as long as
the button is pressed
--
Encoder 1:
ON = connected and registe-
red correctly
Encoder 2:
ON = con-
nected and
registered cor-
rectly
BUS Status:
always ON
OPEN Photocell:
ON = registered
and committed
Opening photocells:
ON = registered and committed
Closing photocells:
ON = registered and com-
mitted
Opening and clo-
sing photocells:
ON = registered and