5 TIMING
Allows you to program:
PAUSE TIME 0…30 s
NIGHT PAUSE TIME: 0…240 s
NIGHT SENSOR DELAY: 0…240 s
■
6 ENERGY SAVING
Allows the Energy Saving function to be enabled/disabled (relative § Section).
■
7 BATTERY KIT
Allows the emergency battery kit to be enabled, specifying the movements carried out
in the various operating modes.
FUNCTION
DISABLED, UNTIL LAST MOVEMENT, LAST MOVEMENT ONLY
LAST MOVEMENT: OPENING, CLOSING
FUNCTION NIGHT
LAST MOVEMENT ONLY, UNTIL LAST MOVEMENT
LAST MOVEMENT NIGHT: OPENING, CLOSING
BATT.LOW OPENING: ENABLED, DISABLED
OPENING TEST: ENABLED, DISABLED
■
8 KIT LOCK
Allows you to program the way the motor block operates (if installed).
TYPE: DISABLED, XB LOCK, XM LOCK (not available for A1000)
FUNCTION
Defines operating modes in which motor block is activated:
DISABLED, NIGHT, NIGHT+MONODIR, NIGHT+OPENED, NIGHT+CLOSED ALWAYS
SURVEILLANCE KIT
ENABLED, DISABLED the surveillance kit on the motor block must be disabled if
it is not installed
FUN. BATTERY
Defines the way the motor block operates when the automation is operating on the
battery:
NIGHT, STANDARD, ALWAYS OPEN
■
9 INSTALLATION
Menu specific to operations carried out during start-up.
MOTOR ROT.
Allows the direction of rotation of the motor to be reversed:
STANDARD, NOT STANDARD (factory setting = STANDARD)
2ND ENGINE KIT
ENABLED, DISABLED enables the double motor kit, if installed
START SETUP
Follow the instructions in the § SETUP section.
Confirm to carry out the SETUP.
INPUTS STATUS
Allows the active inputs to be displayed (see § Diagnostics Section).
DOOR STATUS
Allows the status of the door to be displayed (e.g. SETUP IN PROGRESS).
OTHER BOARD DATA
Allows the following data to be displayed:
V_MAIN input voltage to the board in Volts
V_BATT battery voltage in Volts
V_ACC accessories voltage in Volts
I_MOT motor current draw in Amperes
POS leaf position in cm
■
10 INTERCOM
Program the NODE from the INTERCOM network if provided (relative § Section).
ID
All the menus are described below.
The options that are ONLY available from the SDK EVO are indicated
with (*).
MENU 1 LANGUAGE
Select from the list provided.
MENU 2 PROGRAMMING
i
The menu is only accessible if the TECHNICIAN password has been
entered.
If a different password has been inserted, it is indicated: WRONG
PASSWORD.
■
1 Simply Connect
If you wish to enable Simply Connect, select a channel (CH):
1, 2, 3, 4, 0 = Simply Connect disabled
■
2 DOOR TYPE
Select the model of the automation from the list provided.
SF1400 opens 2 additional menus:
LEAF NUMBER: 1 LEAF, 2 LEAVES
PASSING SPACE.
with 1 LEAF selection: >= 75 cm, <= 65 cm, >65 cm and <75 cm
with 2 LEAVES selection: >= 150 cm, <=130 cm, >130 cm and <150 cm
■
3 INPUTS / OUTPUTS
(*) The NO/NC contact logic can only be programmed via the SDK EVO
(*) The courtesy LIGHT outlet time can only be programmed via the SDK EVO
Select the input or output from the list provided, assign the configuration and select
the type of contact (NO, NC).
INPUTS I1, I2, I3, I4
If an input is configured as a SAFETY, you are required to set the TEST:
ENABLED, DISABLED
OUTPUTS O1/O2
The LIGHT option requires the time to be set: 1…240 s
INPUTS S1-S2
As Inputs I1- I4.
INPUTS E1 / E2
As Inputs I1- I4.
PHOTOCELLS XFA
Allows you to select: DISABLED, 1 PAIR, 2 PAIRS
■
4 MOTION
OPENING
Allows you to program:
SPEED: level 1…10
SLOWDOWN: Slowdown space at end of travel 0…200 cm
SLOWDOWN SPEED Slowdown speed at end of travel level 1…3
STRENGTH: level 1…10
STRENGTH DURATION: 0.1…3.0 s
ACCELERATION: level 1…10
DECELERATION: level 1…10
CLOSING
Allows you to set the same parameters as found under OPENING.
BRAKING
Allows you to program the deceleration for the reverse movement: level 1…5
STOP MOV
Allows you to bring the stop position forwards with respect to the opening
stop: level 1…10 (0 = minimum distance)