EasyManua.ls Logo

Faber INCA SMART User Manual

Faber INCA SMART
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INSM28GR240
INSM21GR240
INSP28SS240
INCA SMART
Installation Instructions
Use and Care Information
Instructions d'installation
Utilisez et d'entretien
Instrucciones de instalación
Información de uso y cuidado

Other manuals for Faber INCA SMART

Question and Answer IconNeed help?

Do you have a question about the Faber INCA SMART and is the answer not in the manual?

Faber INCA SMART Specifications

General IconGeneral
Width52 cm
TypeBuilt-in
LightingLED
Number of Speeds3
Number of Lights2
Grease Filter TypeAluminium

Summary

Installation and Use Guide

Introduction to Use and Care

Provides guidance on operating and maintaining the range hood for optimal performance.

General Safety and Fire Prevention

Grease Fire Safety Measures

Details precautions to prevent range top grease fires and actions to take if a fire occurs.

Electrical and Injury Hazard Warnings

Warns against improper use, provides servicing safety, and highlights electrical shock risks.

Installation and Venting Requirements

Venting Specifications and Sealing

Outlines necessary ductwork, sealing, and material specifications for proper exhaust.

Cold Weather Installation Considerations

Provides guidance on installing draft dampers and thermal breaks for cold climates.

Electrical Setup and Safety

Grounding and Electrical Connection Safety

Details requirements for proper electrical grounding to prevent shock and fire hazards.

California Proposition 65 Chemical Warning

States product contains chemicals known to cause cancer or reproductive harm in California.

Range Hood Dimensional Specifications

21-Inch Model Dimensions

Provides detailed measurements and diagrams for the 21-inch Inca Smart range hood.

28-Inch Model Dimensions

Provides detailed measurements and diagrams for the 28-inch Inca Smart range hood.

Installation Height Guidelines

Clearance Over Cooking Surfaces

Specifies minimum vertical clearance over electric and gas cooking surfaces for safe installation.

Warning: Pro-Style Cooktop Installation

Warns against installing over pro-style cooking surfaces as it voids the warranty.

Product Components and Parts List

Major Product Components

Lists the main parts of the hood, including body, controls, filters, and blower.

Installation Hardware and Tools

Details the screws and tools required for installing the range hood.

Included Documentation

Mentions the inclusion of an instruction manual with the product.

Accessories, Tools, and Installation Safety

Required Ductwork and Custom Liners

Lists necessary ductwork and optional stainless steel liners for custom installations.

Optional Activated Charcoal Filter

Describes the activated charcoal filter accessory for recirculation mode.

Safety Precautions for Installation

Highlights the need for two people and wearing gloves during installation.

Custom Liner Dimensions and Selection

24-Inch Liner Specifications

Displays dimensions for the 24-inch stainless steel liner used with custom hoods.

30-Inch Liner Specifications

Displays dimensions for the 30-inch stainless steel liner used with custom hoods.

36-Inch Liner Specifications

Displays dimensions for the 36-inch stainless steel liner used with custom hoods.

Integrating Liners with Custom Hoods

Standard Liner Installation Guide

Explains how to integrate standard liners into custom or wood hoods for a sealed finish.

Important Note on Perforated Sections

Advises against removing a specific perforated section during installation with the Inca Smart model.

Choosing Your Ducting Method

Ducted Venting Installation Guide

Illustrates and describes the process for installing ducted venting, including elbow placement advice.

Non-Ducted Recirculation Setup

Explains the setup for recirculation, requiring an activated charcoal accessory and internal venting.

Range Hood Installation: Initial Steps

Filter Removal and Bottom Panel Detachment

Details initial steps: removing grease filters and the hood's bottom panel.

Cabinet Preparation for Hood Mounting

Creating the Cabinet Opening

Instructs on creating the correct size opening in the cabinet bottom for hood installation.

Ensuring Cabinet Accessibility

Emphasizes ensuring the cabinet remains accessible for electrical connections post-installation.

Securing and Fastening the Range Hood

Hood Insertion and Support Locking

Details inserting the hood, securing side supports, and tightening screws for stability.

Screw Usage for Hood Fastening

Specifies the number of screws (12a) to use for fastening, noting model-specific counts.

Finalizing Hood Assembly

Reattaching the Bottom Panel

Guides on reattaching the bottom panel using screws (12b).

Installing the Grease Filters

Instructs on correctly placing the grease filters back into the hood.

Ducting and Recirculation System Connections

Ducted Venting Connections

Details installing the damper and connecting ductwork to the roof or wall cap.

Recirculation Grill and Ducting

Explains how to install the recirculation grill and secure it with screws.

Electrical Installation and Grounding Procedures

Proper Grounding for Electrical Safety

Emphasizes the importance of proper grounding for safety and details how to achieve it.

Electrical Connection Safety Advice

Advises against extension cords and consulting electricians for proper grounding and outlet installation.

Recirculation Filter Installation

Inserting Charcoal Filters

Details the process of inserting the activated charcoal filters behind the grease filters for recirculation.

Operating Controls: INSM28GR240 / INSM21GR240

Button and Speed Control Functions

Explains the function of each button and speed control for the INSM28GR240 and INSM21GR240 models.

Operating Controls: INSP28SS240

Control Functions and Indicators

Details the functions of buttons and speed controls, including intensive speed, for the INSP28SS240 model.

Maintenance and Cleaning Guide

Cleaning Metal Grease Filters

Provides instructions on how to clean the metal grease filters by hand or in a dishwasher.

Cleaning Exterior Hood Surfaces

Offers guidance on cleaning the hood's exterior, recommending specific cleaners for different finishes.

Replacing Activated Charcoal Filters

Explains when and how to replace the activated charcoal filters for recirculation systems.

Light Bulb Replacement Procedure

Steps for Replacing Hood Lamps

Outlines the steps to replace the light bulbs, including removing filters and the bottom panel.

Wiring Diagrams: INSM28GR240 / INSM21GR240

Electrical Schematic for INSM28/INSM21

Presents the electrical schematic for the INSM28GR240 and INSM21GR240 models.

Wiring Diagrams: INSP28SS240

Electrical Schematic for INSP28SS240

Provides the electrical schematic for the INSP28SS240 model.

Faber Warranty and Service Information

Understanding Your Product Warranty

Outlines the product warranty, coverage, and how to obtain service.

Warranty Coverage Exclusions

Lists specific items and situations that are not covered by the manufacturer's warranty.

Related product manuals